Selective iodine imaging using lanthanum K fluorescence.

نویسندگان

  • B K Rutt
  • I A Cunningham
  • A Fenster
چکیده

Time-dependent subtraction techniques have tremendously improved the visualization of iodinated vessels. These techniques suffer from motion artifacts, however, since the mask image is acquired several seconds prior to the contrast image. A K-edge subtraction technique for selectively imaging iodine using the characteristic x rays from a lanthanum secondary target is presented. The K alpha lines of lanthanum closely straddle the K edge of iodine. A prepatient iodine filter will alter the ratio of K alpha 1 to K alpha 2 intensities; by subtracting two images made with different K alpha 1/K alpha 2 ratios, iodinated structures can be isolated. Since the method requires no mask image, motion artifacts are reduced. Preliminary images acquired with an image intensifier/photodiode array detector system are shown. Theoretical performance of this method is compared to other iodine-selective imaging techniques on the basis of exposure and dose. The feasibility of using lanthanum K fluorescence for rapid clinical iodine-selective imaging is discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improved Extraction-Separation of Lanthanum/ Europium Ions by Bis(2-ethylhexyl)phosphoric Acid Using 12-Crown-4 as an Ion Selective Masking Agent

The extraction-separation of lanthanum and europium ions with bis(2-ethylhexyl) phosphoric acid (DEHPA) in cyclohexane was improved by adding 12-crown-4 (12C4) to the aqueous phase as a masking agent. In the presence of this crown ether the extraction curve of lanthanum ions versus pH shifts to the higher pH region, while the curve is not influenced for the europium ions. Consequently the s...

متن کامل

Spectral studies on the interaction between lanthanum ion and the ligand: N,N'-ethylenebis-[2-(o-hydroxyphenolic)glycine].

The interaction between N,N'-ethylenebis-[2-(o-hydroxyphenolic)glycine] (EHPG) and lanthanum was studied by the difference UV spectra and fluorescence spectra. At pH 7.4, 0.01 M N-2-hydroxyethylpiperazine-N-2-ethanesulfonic acid (Hepes), with the addition of 1.0 x 10(-3)M lanthanum, two new peaks were observed at 238 nm and 294 nm by absorptivity spectroscopy compared with blank solution EHPG s...

متن کامل

Time-gated biological imaging by use of colloidal quantum dots.

The long (but not too long) fluorescence lifetime of CdSe semiconductor quantum dots was exploited to enhance fluorescence biological imaging contrast and sensitivity by time-gated detection. Significant and selective reduction of the autofluorescence contribution to the overall image was achieved, and enhancement of the signal-to-background ratio by more than an order of magnitude was demonstr...

متن کامل

In Vivo Fluorescence Imaging Of Fruit Fly With Soluble Quantum Dots

The ability of multi colour fluorescence imaging with water soluble carbon quantum dots (WSCQDs) in organisms and biological tissues has been explored using Drosophila melanogaster (fruit flies). Here we present strategies to visualize different developmental stages and their various internal organs in vivo and in vitro condition with multiple, distinct colors. Their viability and growth were n...

متن کامل

Lanthanum(III) Ion Selective Electrode Based on a New Ionophore

A PVC membrane electrode based on 1-[({[(butylsulfunyl)carbothioyl]disulfanyl} carbothioyl)sulfanyl]butane as a suitable ion carrier for determination of lanthanum(III) ion was prepared. This electrode revealedsuch a good selectivity toward La3+ ion over a wide variety of other metal ions. Some experimental parametersuch as membrane composition, nature, and amount of plasticizer, the amount of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 10 6  شماره 

صفحات  -

تاریخ انتشار 1983