Tissue coverage of a hydrophilic polymer-coated zotarolimus-eluting stent vs. a fluoropolymer-coated everolimus-eluting stent at 13-month follow-up: an optical coherence tomography substudy from the RESOLUTE All Comers trial

نویسندگان

  • Juan Luis Gutiérrez-Chico
  • Robert Jan van Geuns
  • Evelyn Regar
  • Willem J. van der Giessen
  • Henning Kelbæk
  • Kari Saunamäki
  • Javier Escaned
  • Nieves Gonzalo
  • Carlo di Mario
  • Francesco Borgia
  • Eveline Nüesch
  • Héctor M. García-García
  • Sigmund Silber
  • Stephan Windecker
  • Patrick W. Serruys
چکیده

AIMS To compare the tissue coverage of a hydrophilic polymer-coated zotarolimus-eluting stent (ZES) vs. a fluoropolymer-coated everolimus-eluting stent (EES) at 13 months, using optical coherence tomography (OCT) in an 'all-comers' population of patients, in order to clarify the mechanism of eventual differences in the biocompatibility and thrombogenicity of the devices. METHODS AND RESULTS Patients randomized to angiographic follow-up in the RESOLUTE All Comers trial (NCT00617084) at pre-specified OCT sites underwent OCT follow-up at 13 months. Tissue coverage and apposition were assessed strut by strut, and the results in both treatment groups were compared using multilevel logistic or linear regression, as appropriate, with clustering at three different levels: patient, lesion, and stent. Fifty-eight patients (30 ZES and 28 EES), 72 lesions, 107 stents, and 23 197 struts were analysed. Eight hundred and eighty-seven and 654 uncovered struts (7.4 and 5.8%, P= 0.378), and 216 and 161 malapposed struts (1.8 and 1.4%, P= 0.569) were found in the ZES and EES groups, respectively. The mean thickness of coverage was 116 ± 99 µm in ZES and 142 ± 113 µm in EES (P= 0.466). No differences in per cent neointimal volume obstruction (12.5 ± 7.9 vs. 15.0 ± 10.7%) or other areas-volumetric parameters were found between ZES and EES, respectively. CONCLUSION No significant differences in tissue coverage, malapposition, or lumen/stent areas and volumes were detected by OCT between the hydrophilic polymer-coated ZES and the fluoropolymer-coated EES at 13-month follow-up.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The prognostic utility of the SYNTAX score on 1-year outcomes after revascularization with zotarolimus- and everolimus-eluting stents: a substudy of the RESOLUTE All Comers Trial.

OBJECTIVES This study assessed the ability of the SYNTAX score (SXscore) to stratify risk in patients treated with percutaneous coronary intervention (PCI) using zotarolimus-eluting or everolimus-eluting stents. BACKGROUND The SXscore can identify patients treated with PCI who are at highest risk of adverse events. METHODS The SXscore was calculated prospectively in 2,033 of the 2,292 patie...

متن کامل

Vascular response to bioresorbable polymer sirolimus-eluting stent vs. permanent polymer everolimus-eluting stent at 9-month follow-up: an optical coherence tomography sub-study from the CENTURY II trial

AIMS The Ultimaster bioresorbable polymer sirolimus-eluting stent (BP-SES) is a newly developed drug-eluting stent (DES) that consists of a thin-strut, cobalt chromium with bioresorbable polymer coated only albuminally. We sought to compare tissue coverage in coronary lesions treated with BP-SES with the XIENCE permanent polymer everolimus-eluting stent (PP-EES) using optical coherence tomograp...

متن کامل

Comparison of zotarolimus- and everolimus-eluting coronary stents: final 5-year report of the RESOLUTE all-comers trial.

BACKGROUND Newer-generation drug-eluting stents that release zotarolimus or everolimus have been shown to be superior to the first-generation drug-eluting stents. However, data comparing long-term safety and efficacy of zotarolimus- (ZES) and everolimus-eluting stents (EES) are limited. RESOLUTE all-comers (Randomized Comparison of a Zotarolimus-Eluting Stent With an Everolimus-Eluting Stent fo...

متن کامل

Unrestricted randomised use of two new generation drug-eluting coronary stents: 2-year patient-related versus stent-related outcomes from the RESOLUTE All Comers trial.

BACKGROUND In the RESOLUTE All Comers trial, the Resolute zotarolimus-eluting stent was non-inferior to the Xience V everolimus-eluting stent for the primary stent-related endpoint of target lesion failure (cardiac death, target vessel myocardial infarction, and ischaemia-driven target lesion revascularisation) at 1 year. However, data for long-term safety and efficacy from randomised studies o...

متن کامل

Angiographic and clinical comparison of novel Orsiro Hybrid sirolimus-eluting stents and Resolute Integrity zotarolimus-eluting stents in all-comers with coronary artery disease (ORIENT trial): study protocol for a randomized controlled trial

BACKGROUND The Orsiro Hybrid sirolimus-eluting stent is a newly developed third-generation drug-eluting stent, featuring a unique dual-polymer mix. An active bioabsorbable polymer delivers the anti-proliferative drug, sirolimus, via controlled release, while a passive biocompatible polymeric coating shields the metallic strut from surrounding tissue, preventing interaction. To date, the Orsiro ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 32  شماره 

صفحات  -

تاریخ انتشار 2011