Pulse Wave Transit Time Measurements of Cardiac Output in Septic Shock Patients: A Comparison of the Estimated Continuous Cardiac Output System with Transthoracic Echocardiography
نویسندگان
چکیده
BACKGROUND We determined reliability of cardiac output (CO) measured by pulse wave transit time cardiac output system (esCCO system; COesCCO) vs transthoracic echocardiography (COTTE) in mechanically ventilated patients in the early phase of septic shock. A secondary objective was to assess ability of esCCO to detect change in CO after fluid infusion. METHODS Mechanically ventilated patients admitted to the ICU, aged >18 years, in sinus rhythm, in the early phase of septic shock were prospectively included. We performed fluid infusion of 500 ml of crystalloid solution over 20 minutes and recorded CO by EsCCO and TTE immediately before (T0) and 5 minutes after (T1) fluid administration. Patients were divided into 2 groups (responders and non-responders) according to a threshold of 15% increase in COTTE in response to volume expansion. RESULTS In total, 25 patients were included, average 64±15 years, 15 (60%) were men. Average SAPSII and SOFA scores were 55±21.3 and 13±2, respectively. ICU mortality was 36%. Mean cardiac output at T0 was 5.8±1.35 L/min by esCCO and 5.27±1.17 L/min by COTTE. At T1, respective values were 6.63 ± 1.57 L/min for esCCO and 6.10±1.29 L/min for COTTE. Overall, 12 patients were classified as responders, 13 as non-responders by the reference method. A threshold of 11% increase in COesCCO was found to discriminate responders from non-responders with a sensitivity of 83% (95% CI, 0.52-0.98) and a specificity of 77% (95% CI, 0.46-0.95). CONCLUSION We show strong correlation esCCO and echocardiography for measuring CO, and change in CO after fluid infusion in ICU patients.
منابع مشابه
Comparison of esCCO and transthoracic echocardiography for non-invasive measurement of cardiac output intensive care.
BACKGROUND The esCCO monitor (ECG- estimated Continuous Cardiac Output, Nihon Kohden(®)) is a new non-invasive tool for estimating cardiac output (CO). It derives CO from the pulse wave transit time (PWTT) estimated by the ECG and the plethysmographic wave. An initial calibration is needed to refine the relation linking pulse pressure (measured by arterial pressure cuff) to PWTT. To assess the ...
متن کاملDeclaration of Interest Declaration of Interest Challenges with Improving Outcomes after Emergency Surgery
1 Bataille B, Bertuit M, Mora M, et al. Comparison of esCCO and transthoracic echocardiography for non-invasive measurement of cardiac output intensive care. Br J Anaesth 2012; 109: 879–86 2 Ishihara H, Okawa H, Tanabe K, et al. A new non-invasive continuous cardiac output trend solely utilizing routine cardiovascular monitors. J Clin Monit Comput 2004; 18: 313–20 3 Yamada T, Tsutsui M, Sugo Y,...
متن کاملA System for Continuous Estimating and Monitoring Cardiac Output via Arterial Waveform Analysis
Background: Cardiac output (CO) is the total volume of blood pumped by the heart per minute and is a function of heart rate and stroke volume. CO is one of the most important parameters for monitoring cardiac function, estimating global oxygen delivery and understanding the causes of high blood pressure. Hence, measuring CO has always been a matter of interest to researchers and clinicians. Sev...
متن کاملAbility of esCCO to track changes in cardiac output.
BACKGROUND We investigated whether cardiac output measured with pulse wave transit time (esCCO, Nihon Kohden, Tokyo, Japan) is able to track changes in cardiac output induced by an increase in preload (volume expansion/passive leg-raising) or by changes in vasomotor tone (variation in norepinephrine dosage) in critically ill patients. METHODS Eighty patients for whom the decision to give flui...
متن کاملContinuous and Cuffless Blood Pressure Monitoring Based on ECG and SpO2 Signals By Using Microsoft Visual C Sharp
Background: One of the main problems especially in operating room and monitoring devices is measurement of Blood Pressure (BP) by sphygmomanometer cuff.Objective: In this study we designed a new method to measure BP changes continuously for detecting information between cuff inflation times by using vital signals in monitoring devices. This will be achieved by extraction of the time difference ...