Implementation of filmarray respiratory viral panel in a core laboratory improves testing turnaround time and patient care.

نویسندگان

  • Min Xu
  • Xuan Qin
  • Michael L Astion
  • Joe C Rutledge
  • Joanne Simpson
  • Keith R Jerome
  • Janet A Englund
  • Danielle M Zerr
  • Russell T Migita
  • Shannon Rich
  • John C Childs
  • Anne Cent
  • Mark A Del Beccaro
چکیده

The FilmArray respiratory virus panel detects 15 viral agents in respiratory specimens using polymerase chain reaction. We performed FilmArray respiratory viral testing in a core laboratory at a regional children's hospital that provides service 24 hours a day 7 days a week. The average and median turnaround time were 1.6 and 1.4 hours, respectively, in contrast to 7 and 6.5 hours documented 1 year previously at an on-site reference laboratory using a direct fluorescence assay (DFA) that detected 8 viral agents. During the study period, rhinovirus was detected in 20% and coronavirus in 6% of samples using FilmArray; these viruses would not have been detected with DFA. We followed 97 patients with influenza A or influenza B who received care at the emergency department (ED). Overall, 79 patients (81%) were given oseltamivir in a timely manner defined as receiving the drug in the ED, a prescription in the ED, or a prescription within 3 hours of ED discharge. Our results demonstrate that molecular technology can be successfully deployed in a nonspecialty, high-volume, multidisciplinary core laboratory.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Respiratory virus detection in immunocompromised patients with FilmArray respiratory panel compared to conventional methods.

Respiratory virus infections cause significant morbidity and mortality in immunocompromised patients. Timely diagnosis is needed to provide optimal clinical care. Diagnostic tests routinely available at most institutions are limited by poor sensitivity and a slow turnaround time. We collected 90 respiratory samples from 87 immunocompromised patients (56 bronchoalveolar lavage and 34 nasopharyng...

متن کامل

Multiplex viral polymerase chain reaction testing using the FilmArray device compared with direct fluorescent antibody testing.

Advances in fluidics, electronics, and instrument design have enabled automation of complex molecular assays. The FilmArray Respiratory Panel (RP) is one such assay; it allows for rapid detection of multiple viral and bacterial respiratory targets via nested polymerase chain reaction (PCR), with all components contained within a single pouch. We performed a detailed comparison of workflow betwe...

متن کامل

Molecular point-of-care testing for respiratory viruses versus routine clinical care in adults with acute respiratory illness presenting to secondary care: a pragmatic randomised controlled trial protocol (ResPOC)

BACKGROUND Respiratory viruses are associated with a huge socio-economic burden and are responsible for a large proportion of acute respiratory illness in hospitalised adults. Laboratory PCR is accurate but takes at least 24 h to generate a result to clinicians and antigen-based point-of-care tests (POCT) lack sensitivity. Rapid molecular platforms, such as the FilmArray Respiratory Panel, have...

متن کامل

Testing implications of varying targets for Bordetella pertussis: comparison of the FilmArray Respiratory Panel and the Focus B. pertussis PCR assay

BACKGROUND The FilmArray Respiratory Panel (RP) detects multiple pathogens, including Bordetella pertussis. The multiplex PCR system is appropriate for a core laboratory or point of care due to ease of use. The purpose of this study is to compare the analytical sensitivity of the FilmArray RP, which targets the promoter region of the B. pertussis toxin gene, with the Focus real-time PCR assay, ...

متن کامل

Multicenter evaluation of the BioFire FilmArray gastrointestinal panel for etiologic diagnosis of infectious gastroenteritis.

The appropriate treatment and control of infectious gastroenteritis depend on the ability to rapidly detect the wide range of etiologic agents associated with the disease. Clinical laboratories currently utilize an array of different methodologies to test for bacterial, parasitic, and viral causes of gastroenteritis, a strategy that suffers from poor sensitivity, potentially long turnaround tim...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of clinical pathology

دوره 139 1  شماره 

صفحات  -

تاریخ انتشار 2013