The Use of a Tuning Fork and Stethoscope Versus Clinical Fracture
نویسندگان
چکیده
Traditional fracture testing in the field of athletic training relies heavily on subjective responses of the athlete. Percussion and compression type tests rely on the athlete stating an increase in pain which represents a positive symptom of a possible fracture. The tuning fork and stethoscope method relied purely on a subjective assessment from the examiner. The purpose of the study was to determine if the use of a 128Hz tuning fork and stethoscope were effective evaluation tools in the assessment of possible fractures as compared to the traditional fracture tests that are used in the athletic training field. A vibrating 128 Hz tuning fork was placed on the bone/area where swelling was minor to facilitate good cortical bone contact. Then the conical bell of a stethoscope was placed on the opposite end on the bone or bones. A diminished sound arising from the injured bone as compared to the uninjured represented a positive sign for a possible fracture. Traditional fracture testing was performed and noted. An x-ray, diagnosed by an orthopedic physician, supported the validity of the tuning fork and traditional fracture testing methods. The attempt was to see what testing method, the tuning fork and stethoscope or traditional fracture testing, was a more valid evaluation tool when it comes to fractures. This study was performed at a university’s athletic training room and a local orthopedic center. The study consisted of any subject between the ages of 18-85 that presented with a suspected fracture at either testing facilities. The current study examined 37 male and female subjects whose age ranged from 18-85 years old. The long bones that were tested in this research were as follows: the phalanges of the hand and foot, metacarpals, metatarsals, humerus, radius, ulna, fibula (including the lateral malleolus), and tibia (including the medial malleolus). The tuning fork and stethoscope was shown to be an effective and valid tool for evaluating possible fractures by yielding a success rate of 89.2% when compared to an x-ray. The percussion and compression fracture testing methods yielded only a success rate of 67.6% and 64.9% respectively.
منابع مشابه
Reliability of Semmes-Weinstein Monofilaments and Tuning Fork on Pressure and Vibration Sensation Measurements in Diabetic Patients
Objectives: Sensory neuropathy is the major cause of ulceration in diabetic patients. Periodical sensory examination is an appropriate method to detect neuropathy and decrease the risk of diabetic foot ulcer. Semmes–Weinstein Monofilaments (SWM) and tuning fork on/off test are widely used to assess pressure and vibration sensitivity. The present study evaluated the inter- and intra-rater reliab...
متن کاملIs there sufficient evidence for tuning fork tests in diagnosing fractures? A systematic review
OBJECTIVE To determine the diagnostic accuracy of tuning fork tests for detecting fractures. DESIGN Systematic review of primary studies evaluating the diagnostic accuracy of tuning fork tests for the presence of fracture. DATA SOURCE We searched MEDLINE, CINAHL, AMED, EMBASE, Sports Discus, CAB Abstracts and Web of Science from commencement to November 2012. We manually searched the refere...
متن کاملRinne revisited: steel versus aluminum tuning forks.
OBJECTIVE (1) Determine whether tuning fork material (aluminum vs stainless steel) affects Rinne testing in the clinical assessment of conductive hearing loss (CHL). (2) Determine the relative acoustic and mechanical outputs of 512-Hz tuning forks made of aluminum and stainless steel. STUDY DESIGN Prospective, observational. SETTING Outpatient otology clinic. SUBJECTS AND METHODS Fifty su...
متن کاملمقایسه اندازه گیری فشارخون توسط گوشی معمولی با گوشی تلفیقی
Background and Purpose: Blood pressure (BP) is routinely evaluated intermittently during the clinical status for care and treatment. The most common method to measure BP is by using the sphygmomanometer with a stethoscope. This method may be difficult for medical students that will use BP for medical evaluation. The purpose of this study was to compare the accuracy of double stethoscope devic...
متن کاملValidation of tuning fork test in stress fractures and its comparison with radionuclide bone scan.
BACKGROUND Stress fractures are quite common both in athletes and military recruits. The purpose of the study was to evaluate the efficacy of tuning fork in stress fractures by comparing it with three phase bone scan. METHODS The current study examined 55 subjects whose age ranged 18-28 years. X-rays of all the subjects were unremarkable. After history and clinical examination tuning fork tes...
متن کامل