Reliability of Passive Hip Extension Mechanical Parameters in Healthy Subjects

نویسندگان

  • Anabèle Brière
  • Denis Gravel
  • Sylvie Nadeau
چکیده

Objective: The objective was to estimate the reliability of three stiffness parameters (moment, angle and stiffness coefficient) of the hip extension movement, for three knee positions. Design: Twenty healthy subjects were assessed on two days separated by a one-week interval. A modified Biodex dynamometer was used to move the right lower limb passively in a side-lying position and to record the hip angle and moment during the movement. Three trials with the knee positioned at 0°, 45° and 90° of flexion were performed each day. Passive stiffness was quantified by three parameters derived from the moment-angle curve of each subject. The generalizability theory was used to determine the reliability coefficients and standard errors of measurement (SEM) computed for a design comprising five trials in one day. Results: Overall, the reliability coefficients were moderate to good with values ranging from 0.58 to 0.83 at the three knee positions. The highest SEM values were 4.15 Nm, 8.4° and 0.15 Nm/° for the moment, angle and stiffness coefficient parameters, respectively. The main source of error variance was related to the subject-day interaction factor and a systematic day effect was also noted. Conclusions: This study constitutes a first step towards objective evaluation of hip extension joint stiffness. Future studies will be needed to better control the alignment of the hip to reduce the systematic day error on the stiffness parameters.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Passive hip range of motion is reduced in active subjects with chronic low back pain compared to controls.

BACKGROUND Non-specific low back pain is a common condition often without a clear mechanism for its presentation. Recently more attention has been placed on the hip and its potential contributions to non-specific chronic low back pain (NSCLBP). Emphasis in research has mainly been placed on motor control, strength and endurance factors in relation to NSCLBP. Limited focus has been placed on hip...

متن کامل

Reliability of Measuring Lumbar Lordosis, Flexion and Extension Using Dual Inclinometer in Healthy Subjects and Patients with Non-Specific Chronic Low Back Pain

Objective: Accurate assessment of lumbar range of motion is of great value for both evaluating lumbar functions and monitoring treatment progress. Recent research indicates that there is no general consensus on the most valid and reliable method of measuring spinal range of motion. The purpose of this study was to determine the intra-rater reliability of lumbar flexion and extension measurement...

متن کامل

بررسی خواص ویسکوالاستیک گشتاور غیر فعال در حرکت اکستنشن و فلکشن مفصل آرنج

 Background: Many researches have been conducted inorder to explore the ingredients of joint impairements like muscle spasticity and joint rigidity in which mechanical viscoelastic properties have been quantified during the joint movement. The aim of this study was to explore passive viscose and elastic properties at flexion and extension of the human elbow joint and to determine a mat...

متن کامل

بررسی ارتباط انعطاف پذیری ران و مچ پا با کنترل پوسچرال سالمندان

Objective: Falling is a common problem in elderly. Researches show that impairment of balance and postural control plays a major role in falling. It is suggested that there is a positive correlation between hip and ankle flexibility and falling in elderly. This study aimed to determine if there is a correlation between hip ankle flexibility and postural balance in elderly Materials & Method...

متن کامل

Reliability and precision of hip proprioception methods in healthy individuals.

OBJECTIVE The goal of this study was to establish the intrasession and intersession reliability and precision of threshold to detect passive motion (TTDPM), force sense (FS), and active joint position sense (JPS) tests for the hip in healthy individuals. DESIGN Descriptive laboratory study. SETTING Research laboratory. PARTICIPANTS Data were collected on 20 subjects between the ages of 18...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009