Prevention of pin tract infection with iodine-supported titanium pins.
نویسندگان
چکیده
BACKGROUND Pin tract infection is one of the most common complications of external fixation. We developed techniques to coat titanium implant surfaces with iodine. This study clinically evaluated the infection-preventive effects and biological safety of iodine-coated external fixation pins. PATIENTS AND METHODS Iodine-supported pins were placed in 39 limbs of 38 patients. The mean age of the patients was 33.6 years. Twenty-six patients were men and 12 were women. In all patients, the iodine-coated pins were used to prevent infection. There were 476 pin insertion sites. Pin sites were classified according to the Checketts-Otterburn classification (grade 1-6). White blood cells (WBC) and C-reactive protein (CRP) were measured pre- and postoperatively in all patients. To confirm whether iodine from the implant affected physiological functions, thyroid hormone levels in the blood were monitored. The change in the amount of iodine deposited in the body over time was calculated by examining the removed pins. RESULTS External fixation was used for a mean duration of 6 months. Grade 1 infection was found in 2.5% of patients, and grade 2 infection in 1.1%. There was no patient with an infection of grade 3 or higher. Median WBC levels were in the normal range, and median CRP levels returned to <0.3 mg/dl within 3 weeks after surgery. Abnormalities of thyroid gland function were not detected. The amount of iodine was maintained for a long time, with approximately 40% remaining after 1 year. CONCLUSIONS Iodine-supported titanium pins were able to decrease the pin tract infection rate and had no impact on thyroid function. These results suggest that iodine-coated titanium pins are biologically safe and effective at preventing pin tract infections.
منابع مشابه
Antibacterial iodine-supported titanium implants.
Deep infection remains a serious complication in orthopedic implant surgery. In order to reduce the incidence of implant-associated infections, several biomaterial surface treatments have been proposed. This study focused on evaluating the antibacterial activity of iodine-supported titanium (Ti-I(2)) and its impact on post-implant infection, as well as determining the potential suitability of T...
متن کاملAntibiotic-coated pins for prevention of pin-tract infection: a rabbit study.
PURPOSE. To evaluate the efficacy of antibiotic-coated pins for prevention of pin tract infection in a rabbit model. METHODS. 10 rabbits were divided into 2 groups. A unilateral external fixator was applied to the tibia with 4 self-taping 1.8-mm pins. In the test group, pins were coated with hydroxyapatite and antibiotic. In the control group, pins were not coated. All pins were then placed in ...
متن کاملCommentary: Antibiotic-coated pins for prevention of pin-tract infection: a rabbit study.
during limb lengthening involving external fixation,1 with an incidence as high as 85%.2 The most appropriate pin-site care is controversial; one study even justifies a nihilistic approach.3 Pin sites near joints are more prone to sepsis, as they are subject to greater movement.4 Minor inflammation or superficial infection is usually treated with antibiotics, local wound care, and occasionally ...
متن کاملThe Half - Pin and the Pin Tract :
A lthough the key principles of external fixation have changed little over the years, there remains a significant amount of variation in fixation methods and postoperative care. In particular, use and management of halfpins intended for prolonged reconstruction are the subject of strong opinions and intense debate. Half-pins are commonly available in stainless steel and titanium. They are also ...
متن کاملInnovative antimicrobial coating of titanium implants with iodine
BACKGROUND Postoperative infection associated with implants remains a serious complication in orthopedic surgery. Several biomaterial surface treatments have been proposed as a means of reducing the incidence of implant-associated infections. In this study, a clinical trial was performed using an iodine-supported titanium that suppresses the microbial activities. METHODS A total of 222 patien...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association
دوره 19 4 شماره
صفحات -
تاریخ انتشار 2014