Human-derived D-dimer for external quality assessment: results of four surveys in Ontario.
نویسندگان
چکیده
External quality assessment (EQA) of D-dimer assays has been limited by a lack of standardized human-derived testing material. In 2006 and 2007, the Quality Management Program--Laboratory Services, Toronto, Canada, investigated the use of commercially prepared lyophilized human plasma spiked with human-derived D-dimer components manufactured by Affinity Biologicals, Hamilton, Canada. Four surveys were performed. Participants reported the level or presence of D-dimer using quantitative or qualitative methods. Participants performing quantitative testing provided their unit of measure and reference interval. Results were considered correct if they fell within the range appropriate for each sample (normal/negative or abnormal/positive). Overall, survey results were excellent, with 4.0% (95% confidence interval [CI], 1.3%-9.1%), 0.8% (CI, 0.0%-1.5%), 2.3% (CI, 0.5%-6.6%), and 2.3% (CI, 0.4%-6.6%) of participants reporting an incorrect result in the first, second, third, and fourth surveys, respectively. A commercially prepared D-dimer is a suitable material for EQA testing.
منابع مشابه
Measuring the effectiveness of human resource information systems in national iranian oil company an empirical assessment
While the growth of MIS investment and its influence is making MIS evaluation ever more indispensable, little attention has been paid to assessing and communicating system effectiveness. This paper attempts to empirically assess the effectiveness of integrated human resource information system in Iranian oil industry. As suggested by recent research, the widely accepted IS success model is...
متن کاملThe value of D-Dimer as a biomarker in assessing disease severity and mortality in patients with Covid-19, a review study
The Covid-19 pandemic created by the 2019 Coronavirus-nCov has become one of the biggest health problems of the current century. Because this disease is new in human society and has no previous history, so our information about it is incomplete, and researchers are trying to study with extensive clinical studies and changes in the human body caused by the function of this virus. It is clear tha...
متن کاملKarstic water exploration using the Schlumberger VES and dipole–dipole resistivity profiling surveys in the Tepal area, west of Shahrood, Iran
The need for clean groundwater resources to have sustainable development in a country is undoubted. Due to the importance and high quality of karstic waters in supplying water in Iran especially in Shahrood city, it is attempted in this research work to recognize and explore karstic waters in southwest of Tepal area, Shahrood. For this purpose, integration of the results obtained from the metho...
متن کاملThe Effect of Preanalytical, Analytical, and Postanalytical Variables on D-dimer Measurement
D-dimer is a soluble fibrin degradation product deriving from the plasmin-mediated degradation of cross-linked fibrin. D-dimer can hence be considered a biomarker of activation of coagulation and fibrinolysis, and it is routinely used for ruling out venous thromboembolism (VTE). D-dimer is increasingly used to assess the risk of VTE recurrence and to help define the uoptimal duration of anticoa...
متن کاملEvaluation of Correlation between D-dimer Levels with Disease Severity in Patients with Covid-19 Referred to Hamedan Besat Hospital in 2021-2022
Introduction: The Covid-19 virus affects the hemostasis system in infected people by causing thrombosis and it increases the level of D_dimer. This study was designed and conducted for the evaluation of correlation between D-dimer levels with disease severity in patients with Covid-19 referred to Hamedan Besat hospital. Methods and Materials: 366 patients with Covid-19 referred to Besat Hospit...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- American journal of clinical pathology
دوره 130 5 شماره
صفحات -
تاریخ انتشار 2008