The effect of fluoride exposure on the load-deflection properties of superelastic nickel-titanium-based orthodontic archwires.

نویسندگان

  • Farzaneh Ahrari
  • Barat-Ali Ramazanzadeh
  • Berahman Sabzevari
  • Ali Ahrari
چکیده

BACKGROUND It has been demonstrated that fluoride prophylactic agents may cause hydrogen absorption in NiTi wires and degrade their mechanical properties. AIMS To investigate the effect of a fluoride mouthwash on load-deflection characteristics of three types of nickel-titanium-based orthodontic archwires. METHODS Twenty maxillary 0.016 inch round specimens from each of the single-strand NiTi (Rematitan 'Lite'), multi-strand NiTi (SPEED Supercable) and Copper NiTi (Damon Copper NiTi) wires were selected. The specimens were kept in either 0.2% NaF or artificial saliva solutions at 37 degrees C for 24 hours (N = 10). The wire load-deflection properties were measured by a Zwick testing machine, using a three-point bending test. An un-paired student's t-test, a one-way ANOVA and a Tukey post-hoc test were used to assess statistical significance. RESULTS Immersion in NaF solution affected the load-deflection properties of NiTi wires. The unloading forces at 0.5 and 1.0 mm deflections were significantly lower in fluoride-treated specimens compared with the control groups (p < 0.05). Unloading forces at 1.5, 2.0 and 2.5 mm deflections were not statistically different between fluoride- and saliva-treated specimens (p > 0.05). CONCLUSIONS The results suggested that subjecting NiTi wires to fluoride agents decreased associated unloading forces, especially at lower deflections, and may result in delayed tooth alignment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the Effect of an Experimental Herbal versus Fluoridated Mouthwash on Frictional Resistance and Surface Roughness between Orthodontic Brackets and Two Types of Archwire: In Vitro Study

Introduction: The present study aimed to evaluate an experimental herbal mouthwash, as compared to sodium fluoride mouthwash on the frictional resistance and surface roughness between brackets and two rectangular archwire types. Methods: A total of 60 premolar׳s brackets engaged with 0.019×0.025 archwires made of stainless steel and nickel-titanium alloys were used in this study. The samples we...

متن کامل

Force-deflection properties of initial orthodontic archwires.

AIM This in vitro study measured the force-deflection behavior of selected initial alignment archwires by conducting three-point bending tests under controlled conditions. The study tested four wire designs: multistranded stainless steel, conventional stainless steel, superelastic nickel-titanium, and thermoactivated nickel-titanium archwires. METHOD The wires (n = 15) were ligated into stain...

متن کامل

Effects of Fluoride on NiTi Orthodontic Archwires: An X-ray Diffraction Study

Objective: To explore the changes in nickel-titanium (NiTi) archwires after exposure to fluoride-containing acetic acid solutions. Materials and methods: Preformed rectangular NiTi wires were immersed in either an acidulated fluoride solution, a neutral fluoride solution or distilled water (control) for 1.5 hours at 37°C. After immersion, the unloading force values at four deflection points wer...

متن کامل

Comparison of the superelasticity of different nickel–titanium orthodontic archwires and the loss of their properties by heat treatment

The aim of this work is to describe and compare mechanical properties of eight widely used nickel-titanium orthodontic wires under uniform testing conditions and to determine the influence of the heat treatments on the loss of the superelasticity. Ten archwires from two batches from eight different manufacturers were evaluated. A three-point bending test was performed, in accordance with ISO 15...

متن کامل

Mechanical Properties of Copper-Nickel-Titanium Archwires

MECHANICAL PROPERTIES OF COPPER-NICKEL-TITANIUM ORTHODONTIC WIRES Margaret Rosen, D.M.D. Marquette University, 2016 Introduction: The initial phase of orthodontic therapy relies on flexible wires, usually composed of a nickel-titanium alloy, to apply a substantially constant load during tooth movement. Copper has been added to nickel-titanium archwires, resulting in an alloy with potential clin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Australian orthodontic journal

دوره 28 1  شماره 

صفحات  -

تاریخ انتشار 2012