Apps for Radiation Oncology. A Comprehensive Review1

نویسندگان

  • J.J. Calero
  • L.F. Oton
  • C.A. Oton
چکیده

INTRODUCTION Software applications executed on a smart-phone or mobile device ("Apps") are increasingly used by oncologists in their daily work. A comprehensive critical review was conducted on Apps specifically designed for Radiation Oncology, which aims to provide scientific support for these tools and to guide users in choosing the most suited to their needs. MATERIAL AND METHODS A systematic search was conducted in mobile platforms, iOS and Android, returning 157 Apps. Excluding those whose purpose did not match the scope of the study, 31 Apps were methodically analyzed by the following items: Objective Features, List of Functionalities, Consistency in Outcomes and Usability. RESULTS Apps are presented in groups of features, as Dose Calculators (7 Apps), Clinical Calculators (4), Tools for Staging (7), Multipurpose (7) and Others (6). Each App is presented with the list of attributes and a brief comment. A short summary is provided at the end of each group. DISCUSSION AND RECOMMENDATIONS There are numerous Apps with useful tools at the disposal of radiation oncologists. The most advisable Apps do not match the more expensive. Three all-in-one apps seem advisable above all: RadOnc Reference (in English), Easy Oncology (in German) and iOncoR (in Spanish). Others recommendations are suggested for specific tasks: dose calculators, treatment-decision and staging.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comprehensive end-to-end test for intensity-modulated radiation therapy for nasopharyngeal carcinoma using an anthropomorphic phantom and EBT3 film

Background: In head and neck radiotherapy, immobilization devices can affect dose delivery. In this study, a comprehensive end-to-end test was developed to evaluate the accuracy of radiotherapy treatment. Materials and Methods: An Alderson Radiation Therapy (ART) anthropomorphic phantom with EBT3 film was used to mimic the actual patient treatment process. Ten patients treated for nasopharyngea...

متن کامل

Demographic characteristics and prognostic factors in pediatric-type sarcomas; A 7 year single institutional experience and comprehensive review of the current literature

Background: Due to limited clinical data in pediatric-type sarcomas (rhabdomyosarcoma, Ewing's sarcoma, PNET, and desmoplastic small round-cell tumor), the aim of this study was to evaluate the demographic characteristics and identifying prognostic factors for survival. Materials and Methods: We retrospectively reviewed 110 patients with pediatric-type sarcomas. Overall and disease free surviva...

متن کامل

Clinical Medical Physicist Training Program at Reza Radiotherapy and Oncology Centre (RROC)

Introduction: It has been shown that there is a strong correlation between training and improving the Radiation Oncology Medical Physicist (ROMP) and an Oncology Department Quality Management plans. The Reza Radiotherapy and Oncology Centre (RROC) beside of its development plan, has recently implemented a comprehensive in-site training plan based on ROMPs abilities and the Depa...

متن کامل

Management of bulky high-grade pleomorphic sarcoma using grid therapy technique

In the present study, a case was reported concerning a patient with a bulky extremity soft tissue sarcoma treated with spatially fractionated Grid therapy and then followed by standard external beam radiotherapy. Treatment was performed using a Grid block to deliver 15 Gy in one fraction. There was one week interval break before EBRT treatment with 50 Gy in 25 fractions for the neoadjuvant exte...

متن کامل

Systematic and comprehensive analysis of the dose-response characteristics of a morning quality check of a linear accelerator and an important application of accelerator performance prediction

Background: This paper aimed to analyze the output constancy of a medical linear accelerator using PTW QUICKCHECKwebline and studied the sensitivity of the PTW QUICKCHECKwebline. Materials and Methods:  The paper statistically analyzed the output doses of 6 MV and 10 MV of photons and 6 MeV, 9 MeV, and 12 MeV of electrons from a medical linear accelerator measured before the daily treatment to ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2017