Validation of multiple-breath washout equipment: from bench to clinic and possible pitfalls.

نویسندگان

  • Philipp Latzin
  • Bruce Thompson
چکیده

much more widely used, such as spirometry, body plethysmography or T L CO . Before results of MBW can be compared between centres or even multi-centre trials can be performed, these kinds of validation studies are extremely important to guarantee comparability and identify sources of errors. In this regard, Gonem et al. [15] are to be congratulated for the thorough validation study of the Innocor system published in this issue of Respiration . The authors do not hesitate to report openly the current drawbacks of the equipment and nicely show that functional residual capacity (FRC) underestimation at low lung volumes will result in a very relevant overestimation of LCI at those low lung volumes [15] . These results are surprising as they oppose the previous assumption that LCI might be more robust to measurement errors compared to FRC, as LCI is a ratio of lung volumes and possible measurement errors might cancel out. This is not the case, and the measured overestimation in LCI is clinically important. Moreover, this type of error may be problematic when using the same equipment in patients with a wide age range, leading to incorrect physiological conclusions based on possible technical issues [16, 17] . In recent years, there has been a renaissance of studies using multiple-breath washout (MBW) tests in different populations with varying lung diseases. To date, measures obtained from the MBW have followed two parallel paths. First, the lung clearance index (LCI) has been shown to be a sensitive marker of cystic fibrosis and applicable in routine clinical practice or as study outcome in a predominantly paediatric population [1– 6] . Other outcomes, such as the slope of phase III parameters (S acin and S cond ), have been found to predict disease course in asthmatic patients [7–10] and other respiratory conditions, but predominantly in adult populations [11–13] . An important outcome of this renaissance is the recently published ERS/ATS consensus statement on inert gas washout tests [14] . This document gives an overview on existing techniques, practical suggestions with regard to the measurement itself and clear advice for validating new equipment. Importantly, it highlights the need for further characterization and validation work with regard to the test procedure, equipment and analysis methods. This cannot be emphasized enough, as comparable validation studies were never done for basic tests that are Published online: April 24, 2014

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multiple-breath nitrogen washout techniques: including measurements with patients on ventilators.

Definition ....................................................................... Methods for determining FRC ................................... Choice of method FRC measured by plethysmography (FRCpleth) ......... FRC measured by helium dilution (FRCHe) ............. FRC measured by nitrogen washout (FRCN2) ........... Standards for lung volume measurement by gas dilution/washout techniques ...

متن کامل

Consensus statement for inert gas washout measurement using multiple- and single- breath tests.

Inert gas washout tests, performed using the single- or multiple-breath washout technique, were first described over 60 years ago. As measures of ventilation distribution inhomogeneity, they offer complementary information to standard lung function tests, such as spirometry, as well as improved feasibility across wider age ranges and improved sensitivity in the detection of early lung damage. T...

متن کامل

ERS/ATS CONSENSUS STATEMENT Consensus statement for inert gas washout measurement using multiple- and single- breath tests

Inert gas washout tests, performed using the singleor multiple-breath washout technique, were first described over 60 years ago. As measures of ventilation distribution inhomogeneity, they offer complementary information to standard lung function tests, such as spirometry, as well as improved feasibility across wider age ranges and improved sensitivity in the detection of early lung damage. The...

متن کامل

Leaks during multiple-breath washout: characterisation and influence on outcomes

Nitrogen multiple-breath washout (N2MBW) is increasingly used in patients with cystic fibrosis. The current European Respiratory Society/American Thoracic Society consensus statement for MBW recommends the rejection of measurements with leaks. However, it is unclear whether this is necessary for all types of leaks. Here, our aim was to 1) model and 2) apply air leaks, and 3) to assess their inf...

متن کامل

Equipment for multiple breath washout.

5 Demeo DL, Campbell EJ, Barker AF, et al. IL10 polymorphisms are associated with airflow obstruction in severe alpha1-antitrypsin deficiency. We read with interest the article ''Paediatrics in Berlin'' [1] in a recent issue of the European Respiratory Journal, which sum-marised the paediatric topics of the European Respiratory Society's Annual Congress in Berlin. In this article, inert gas mul...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Respiration; international review of thoracic diseases

دوره 87 6  شماره 

صفحات  -

تاریخ انتشار 2014