Effects of transcatheter aortic valve implantation on ascending aorta wall elastic properties: Tissue Doppler imaging and strain Doppler echocardiography study☆
نویسندگان
چکیده
Background Aortic elastic properties are determinants of left ventricular function by means of ventriculo-arterial coupling and indicators of cardiovascular risk. Aortic valve stenosis surgical replacement temporary reduces aortic function damaging vasa vasorum, while transcatheter aortic valve implantation (TAVI) does not influence it in the short term. We studied aortic distensibility, stiffness, M-mode strain and tissue strain after 6 and 12 months from TAVI. Methods We enrolled 15 patients with symptomatic severe aortic stenosis who underwent CoreValve prosthesis (Medtronic, Minneapolis, MN) implantation. Everyone had blood pressure measurement and echocardiography registration before TAVI and after 6 and 12 months. Results After TAVI NYHA class (p = 0.016), peak and mean aortic valve gradients (p < 0.001 for both) improved. Aortic distensibility increased (p = 0.032 in the first 6 months, p = 0.005 in the second 6 months, and p = 0.003 from baseline to 12 months), as well as stiffness decreased (p = 0.034; 0.090; 0.001), M-mode strain and tissue strain ameliorated (p = 0.041; 0.004; 0.004; and p = 0.013; 0.002; 0.001, respectively), tissue Doppler imaging improved (S' wave: p = 0.289; 0.347; 0.018. E' wave: p = 0.018; 0.113; 0.007. A' wave: p = 0.002; 0.532; 0.001). Moreover, some left ventricular parameters improved at 6 months, such as ejection fraction (from 49 ± 16 to 57 ± 11%; p = 0.044) and diastolic interventricular septum thickness (from 14 ± 2 to 12 ± 2 mm; p = 0.010). Even systolic pulmonary artery pressure (p = 0.019) and left diastolic dysfunction grade ameliorated (p = 0.042). Conclusions For the first time we demonstrated that aortic elastic properties improve at 6 and 12 months after TAVI, thus influencing ventriculo-arterial coupling and ameliorating left ventricular function.
منابع مشابه
Cardiac Function and Aortic Valve Intervention - Echocardiographic Studies of Myocardial Recovery in Patients with Severe Aortic Valve Disease
....................................................................................................... 1 POPULÄRVETENSKAPLIG SAMMANFATTNING ................................. 3 LIST OF ORIGINAL PAPERS ........................................................................ 5 ABBREVIATIONS ............................................................................................. 6 INTRODUCTIO...
متن کاملAssessment of the elasticity properties of the ascending aorta in patients with subclinical hypothyroidism by tissue Doppler imaging.
OBJECTIVE We aimed to investigate whether aortic elastic properties were affected in subclinical hypothyroidism (SCH) by using tissue Doppler imaging (TDI). SUBJECTS AND METHODS Forty-three patients with newly diagnosed SCH and forty-eight healthy controls were included to the study. Systolic and diastolic diameters of the ascending aorta were measured by M-mode transthoracic echocardiography...
متن کاملDoppler echocardiographic findings in tissue engineered aortic valve in a sheep model
Background: Heart valve diseases are considered a common disease in human and animals, and valve replacement is an option for treatment of valvular diseases. Objectives: In this study efficacy of a tissue engineered valve in thoracic aorta was evaluated with transthoracic echocardiography. Methods: This study was undertaken on 6 male sheep. Echocardiography was performed on all sheep 24 hours b...
متن کاملEffects of transcatheter aortic valve implantation on left ventricular mass and global longitudinal strain: tissue Doppler and strain evaluation
INTRODUCTION Transcatheter aortic valve implantation is the option of choice for high surgical risk patients suffering from symptomatic aortic stenosis. We aimed to evaluate the influence of baseline global longitudinal strain on left ventricular mass regression after the procedure. METHODS We enrolled 23 patients with pure symptomatic severe aortic stenosis who underwent CoreValve prosthesis...
متن کاملAcute regional improvement of myocardial function after interventional transfemoral aortic valve replacement in aortic stenosis: A speckle tracking echocardiography study
BACKGROUND Transcatheter aortic valve implantation (TAVI) is a promising therapy for patients with severe aortic stenosis (AS) and high perioperative risk. New echocardiographic methods, including 2D Strain analysis, allow the more accurate measurement of left ventricular (LV) systolic function. The goal of this study was to describe the course of LV reverse remodelling immediately after TAVI i...
متن کامل