A Label-free Protein Sensor Based on Mems Fabry-perot Interferometer Integrated with Silicon Photodiode
نویسندگان
چکیده
ABSTRACT We have newly developed a label-free protein sensor based on MEMS Fabry-Perot interferometer integrated with a photodiode, which utilizes nonlinear optical effect of the Fabry-Perot resonance to enhance the sensitivity of surface stress. A parylene was used for a deformable membrane of the protein sensor because of the high optical transmittance and low Young’s modulus. Theoretical signal-to-noise ratio of the proposed sensor with the surface stress of -0.1 N/m with 200 μm diameter using a light source of 10 mW is calculated 1.55 x 10 with the experimental dark current noise of 10 nA in the photodiode which is two orders of magnitude larger than piezoresistive type. A photocurrent was demonstrated to shift by 23.7 nA at 3 V bias voltage with immobilized antibodies.
منابع مشابه
MEMS Navigation-Grade Electro-Optical Accelerometer
Accurately measuring displacement of mechanical components on micro-scale devices is often the limiting factor affecting resolution for many MEMS-based sensors including accelerometers, Coriolis-based gyroscopes, pressure sensors, temperature sensors, and magnetometers. This paper introduces a novel electro-optical displacement detection scheme which has been applied to navigation-grade MEMS ac...
متن کاملA Miniature Fiber Optic Refractive Index Sensor Built in a MEMS-Based Microchannel
A small, highly sensitive, and electromagnetic interference (EMI)-immune refractive index (RI) sensor based on the Fabry-Perot (FP) interferometer is presented. The sensor's FP cavity was fabricated by aligning two metal-deposited, single-mode optical fiber endfaces inside a microchannel on a silicon chip. The mirrors on the fiber endfaces were made of thermal-deposited metal films, which provi...
متن کاملFabry-Perot Diaphragm Fiber Optic Sensor (DFOS) for Acoustic Detection
The diaphragm fiber optic sensor (DFOS) solely based on Fabry-Perot multiple beam interference has been designed and fabricated with Micro-electric mechanical system (MEMS) technology. The silicon diaphragm with an embossed center was designed with an interference gap width kept accurately. The DFOS is verified to be truly and purely of Fabry-Perot type via a critical test. Parallel testing of ...
متن کاملDesign Studies of Integrated Fabry-Perot Sensor Based on Bragg Grating Mirrors
In this work the results of the theoretical studies of photonic integrated circuit refractive index sensor based on quasi1D Bragg grating configurations which act as a Fabry-Perot interferometers are presented. The variation of the medium refractive index is detected by monitoring the shift of the spectral maxima of the Fabry-Perot cavity. The sensor has been designed using the analytical expre...
متن کاملGas Sensor Design Using a Fabry-Perot Interferometer With Long Cavity Length As a Modulator
A gas sensor based on correlation spectroscopy using a FPI with long cavity length (>500 μm) as a modulator is presented. Eventually the FPI and the optical detector will be integrated within a MEMS structure. ©2005 Optical Society of America OCIS codes: (220.4830) Optical systems design; (120.4640) Optical instruments; (120.4570) Optical design of instruments
متن کامل