This report describes the case of a 29-year-old patient, female (nulliparous) who had an intrauterine device (IUD) inserted in 2010 and who has had no gynecological control since then (for 4 years). After this time, the asymptomatic patient had a gynecological appointment, during which a doctor did not find the strings of IUD in the speculum. Ultrasound examination did not reveal the presence of the IUD in the uterine cavity, which led to the suspicion of its presence outside the uterus. The patient was referred to a hospital, where she underwent ultrasound and X-ray examination of the pelvis that confirmed the presence of the IUD outside the uterus. Laparoscopy was performed during which the IUD was localized as being embedded in the omentum. It was removed by performing a resection of a part of the omentum with inflammatory infiltration. The patient was discharged home on the second postoperative day in a good condition. This case confirms the need for gynecological control and ultrasound examination shortly after insertion. An ultrasound or/and X-ray is mandatory in any case of absence of IUD strings previously visible in the vagina, if the patient did not observe its expulsion.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Forgotten Migrated Intrauterine Contraceptive Device Is Not Always Innocent: A Case Report

The incidence of transuterine perforation and migration of intrauterine contraceptive devices (IUCDs) into the abdominal cavity has been estimated at less than 0.1%. It has been suggested that intraperitoneal IUCD have low morbidity and may be left in situ. We report the first case of closed loop small bowel obstruction due to migration of a "Saf-T-Coil" IUCD into the abdominal cavity, where it...

متن کامل

Laparoscopic management of a translocated intrauterine device embedded in the gastric serosa.

Intrauterine devices (IUD) are the most common contraceptive methods all over the world. Besides many advantages, there are also some complications of this method. The most important complication of IUD is uterine perforation. The reported incidence of IUD perforation ranges from 0.2 to 9.6 per thousand insertions. In this article we would like to report a case that has an IUD migrated to the g...

متن کامل

A levonorgestrel-releasing intrauterine system embedded in the omentum in a woman with abdominal pain: a case report

INTRODUCTION The Mirena intrauterine system has been licensed as a contraceptive in the United Kingdom since May 1995. The use of an intrauterine system as a primary method of contraception among women has been slowly increasing over the last few years and they now account for about 3% of contraceptive use in England. The Mirena intrauterine system now also has a license for the management of i...

متن کامل

Intrauterine device embedded in omentum of postpartum patient with a markedly retroverted uterus: a case report

BACKGROUND The intrauterine device is a popular form of long-acting reversible contraception. Although generally safe, one of the most serious complications of intrauterine device use is uterine perforation. Risk factors for perforation include position of the uterus, force exerted during intrauterine device insertion, postpartum period, and breastfeeding. This case is important and needs to be...

متن کامل

The Role of Three Dimensional Transvaginal Ultrasound in Detection of Intrauterine Device Displacement in Post Caesarean Section: A Case Report

Intrauterine Devices (IUDs) are used as an efficient and inexpensive method of contracep¬tion. Contraceptive efficacy depends on the intrauterine location of IUD and intrauterine displacement of the IUD leads to decreased contraceptive efficacy. Expulsion of IUD and its penetration into myometrium is one of the complications of IUD. In cases where IUDs are not detected by ultrasound method, in ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2015