Identification of performance problems in a commercial human immunodeficiency virus type 1 enzyme immunoassay by multiuser external quality control monitoring and real-time data analysis.

نویسندگان

  • J Kim
  • C Swantee
  • B Lee
  • H Gunning
  • A Chow
  • F Sidaway
  • C Sherlock
  • R Garceau
  • W Dimech
  • L Malloch
چکیده

In June 2005, a pilot program was implemented in Canadian laboratories to monitor the performance of the Abbott human immunodeficiency virus types 1 and 2 (HIV-1/2) gO enzyme immunoassay (EIA). Two different external quality control (QC) reagents and a "real-time" software analysis program were evaluated. In November 2005, higher-than-expected calibrator rate values in these kits were first reported at the Ontario Ministry of Health (Etobicoke), followed by the Alberta Provincial Public Health Laboratory (Edmonton and Calgary) and others. These aberrations were easily and readily tracked in "real time" using the external QC reagents and the software program. These high calibrator values were confirmed in Delkenheim, Germany, by Abbott, and a manufacturing change was initiated beginning with lot 38299LU00, which was distributed to laboratories in Canada in April 2006. However, widespread reports of calibrator failure by laboratories outside Canada were made in March 2006. In April 2006, Abbott Diagnostics initiated a level III investigation to identify the root cause, which was prolonged storage, under uncontrolled storage conditions, of the raw material used in the manufacture of the matrix cells. To the best of our knowledge, this is the first example of a program in Canada for serological testing that combines a common external QC reagent and a "real-time" software program to allow laboratories to monitor kit performance. In this case, external QC monitoring helped identify and confirm performance problems in the Abbott HIV-1/2 gO EIA kit, further highlighting the benefit of implementing such a program in a national or multilaboratory setting for laboratories performing diagnostic and clinical monitoring testing.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantification Analysis of Dot Blot Assays for Human Immunodeficiency Virus Type 1 and 2 Antibodies

Objective Dot Blot (DB) assay provides highly specific results, but usually not reliable for quantification of antibody production. The need for a more objective DB assay to provide a better definition of the immune status, against HIV antigens, promoted this study to be done to develop a quantitative DB assay. Material and Methods Dot blot (DB) strips for antibodies directed to human immuno...

متن کامل

Online Monitoring for Industrial Processes Quality Control Using Time Varying Parameter Model

A novel data-driven soft sensor is designed for online product quality prediction and control performance modification in industrial units. A combined approach of time variable parameter (TVP) model, dynamic auto regressive exogenous variable (DARX) algorithm, nonlinear correlation analysis and criterion-based elimination method is introduced in this work. The soft sensor performance validation...

متن کامل

ارزیابی و مقایسه ENZYME IMMUNOASSAY (EIA) و رنگ آمیزی اسید فاست با تایید به روش ایمنو فلورسنت آنتی‌بادی جهت تشخیص گونه‌های کریپتوسپوریدیوم

Introduction: Cryptosporidiosis is prevalent world wide, causing a variety of problems ranging from acute, self-limiting diarrhea to fatal cases in immunocompromised persons, particulary those with acquired immunodeficiency (AIDS). Diagnosis of Cryptosporidium is made by identification of oocysts in stool specimens. The detection is most commonly made by the acid-fast staining method followed b...

متن کامل

طراحی و راه اندازی روش TaqMan Real-time PCR جهت تشخیص و تعیین کمی ویروس نقص ایمنی اکتسابی نوع1 (HIV-1)

Background: Human Immunodeficiency Virus Type 1 (HIV-1) is one of the most important blood-borne infectious viruses that are considered a global problem, thus it is important to diagnose it with high accuracy and sensitivity. Serologic methods do not adequately detect this infection. Therefore, the purpose of the present study was to design a sensitive method based on TaqMan Real-time PCR me...

متن کامل

Molecular identification of reovirus in broiler type flocks in Golestan province, Iran

Background: Avian reovirus (ARV) has a global distribution in nature and most clinical signs are found in broiler type chickens. Aims: This study was conducted to detect and identify reovirus infections from vaccinated breeder chickens and their progenies. Methods: A total of 20 tissue and blood samples were collected from vaccinated broiler br...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 47 10  شماره 

صفحات  -

تاریخ انتشار 2009