Effect of plasma component transfusion on conventional coagulation screening tests
نویسندگان
چکیده
BACKGROUND Conventional coagulation screening tests such as Prothrombin time, International normalized ratio (INR) and activated partial thromboplastin time are often used to predict bleeding in various clinical situations. We aimed to observe the effect of Fresh-frozen plasma (FFP) on these parameters. Methods Patients' demographics, pre- and post-transfusion coagulation parameters were noted to assess the level of correction. The magnitude of improvement in INR was determined using the formula given by Holland and Brooks. Data was analyzed using IBM SPSS Statistics 20. RESULTS Among 2082 episodes, 4991 units of FFP were transfused at an average of 5 units per patient. Median dose of FFP administered per episode was 10 mL/kg (5.8-13.4). The mean change in INR following transfusion was 8.9% of the pre-transfusion INR and thus considered to be statistically significant. CONCLUSION FFP transfusions as a prophylactic measure especially in patients with mildly deranged conventional coagulation screening tests without any empirical evidence of clinical bleeding needs further scrutiny. Reduction in INR following FFP transfusions was better in cohort having higher pre-transfusion INR value (> 3.0).
منابع مشابه
The Effect of Methylene Blue in Combination with Red Visible Light on Model Viruses Inactivation and Coagulation Factors in Fresh Frozen Plasma
Background and Aims: Fresh Frozen Plasma (FFP) is one of blood components. The risk of transmission of viruses from blood components regardless selection of blood donors and screening donated blood still remains. There are several methods for viral inactivation. In this study methylene blue (MB) photo inactivation process was used for inactivating viruses. Materials and Methods: In this study M...
متن کاملThe evidence-based use of FFP and cryoprecipitate for abnormalities of coagulation tests and clinical coagulopathy.
There continues to be a general but unfounded enthusiasm for fresh frozen plasma (FFP) or frozen plasma (FP) usage across a range of clinical specialties in hospital practice. Plasma for transfusion is most often used where there are abnormal coagulation screening tests, either therapeutically in the face of bleeding, or prophylactically in nonbleeding patients prior to invasive procedures or s...
متن کاملThromboelastometry Based Early Goal-Directed Coagulation Management Reduces Blood Transfusion Requirements, Adverse Events, and Costs in Acute Type A Aortic Dissection: A Pilot Study.
BACKGROUND: In aortic surgery bleeding complications can be fatal. Therefore, rotational thromboelastometry(ROTEM™)-based coagulation management was introduced. METHODS: After 5 cases of acute type A aortic dissection and aortic arch replacement had been treated based on ROTEM findings (ROTEM group; RG), 5 cases without ROTEM were matched as control group (CG). CG treatment was based on conven...
متن کاملComparison of conventional coagulation tests and thromboelastography for preoperatively assessing blood loss and transfusion during orthotopic liver transplantation
Objective: An effective blood loss and transfusion requirements assessment before orthotopic liver transplantation (OLT) may improve intraoperative bleeding management during OLT. Methods: Sixty-five patients were included in this retrospective, observational study. Correlations of conventional coagulation tests (CCTs) and TEG parameters with blood loss and transfusions were determined using Pe...
متن کاملThromboelastometry profile in critically ill patients: A single-center, retrospective, observational study
BACKGROUND Transfusion therapy is associated with increased morbidity, mortality and costs. Conventional coagulation tests (CCT) are weak bleeding predictors, poorly reflecting coagulation in vivo. Thromboelastometry (ROTEM) provides early identification of coagulation disorders and can guide transfusion therapy by goals, reducing blood components transfusion. OBJECTIVE The aim of this study ...
متن کامل