Steady-state measurements of respiration rate with an oxygen electrode.
نویسندگان
چکیده
The respirometer is shown in Fig. 1. The cathode was made from gold wire of 0.51 mm diam which was coated with glass of low melting point (4). After mounting the cathode as shown in Fig. 1, the gold and its glass coating were ground to a flat surface and polished using a series of carborundum grinding powders. The cathode was maintained at -0.45 V with respect to the calomel electrode. The electrode current was measured with a Keithley model 15OA microvolt-amperometer (Keithley Instruments, Cleveland, OH 44139). The buffer was 0.01 M succinate at pH 6.0, made with glass-distilled water. At low oxygen tensions, 0.01 M KC1 was used as an electrolyte, but at atmospheric oxygen tension, 0.1 M KC1 was required to prevent appreciable electrolyte resistance between the electrodes. Stirring was done with a magnet rotated at 2000 rpm under the respirometer. The slot along the inner joint of the respirometer was just large enough to accommodate a 26-gauge hypodermic needle. This needle was connected to a syringe pump, and airequilibrated buffer was pumped into the respirometer at a constant rate. The syringe pump was constructed by attaching the chart drive of a Health/Schlumberger model EU-20B recorder (Health/Schlumberger Instruments, Benton Harbor, MI 49022) to the rack and pinion gear
منابع مشابه
Surface Modification of Glassy Carbon Electrode by Ni-Cu Nanoparticles as a Competitive Electrode for Ethanol Electro-Oxidation
In the present study, Nickel-Copper nanoparticles were electrodeposited on glassy carbon electrode (GCE) by using electroplating deposition method. The prepared electrode was characterized by scanning electron microscopy (SEM) and elemental mapping analysis. Results showed that Ni-Cu nanoparticles with a high density are distributed at the surface of the glassy carbon electrode. Subsequentl...
متن کاملDetermination of glucose diffusion coefficients in biofilms with micro-electrodes.
A glucose micro-electrode was developed for direct measurements inside biofilms, and applied for the determination of effective diffusion coefficients in a model system of agar beads containing immobilized yeast cells. Two methods were used, one based on concentration gradients present at the liquid/solid interface of an active biofilm under steady-state conditions, the other based on the rate ...
متن کاملAN ANALYTICAL SOLUTION FOR DIFFUSION AND NONLINEAR UPTAKE OF OXYGEN IN THE RETINA
A simple mathematical model of steady state oxygen distribution subject to diffusive transport and non- linear uptake in a retinal cylinder has been developed. The approximate analytical solution to a reaction- diffusion equation are obtained by using series expansions. The computational results for the scaled variables are presented through graphs. The effect of the important parameters (1) d...
متن کاملRespiratory behavior of turning stage mature tomato (Solanum lycopersicum L.) under closed system at different temperature
The respiration rate and respiratory quotient of mature tomato (Solanum lycopersicum L. cv. ‘Himsona’) fruits harvested at the turning stage were determined under closed system at 5, 10, 15, 20, 25 and 35 °C (ambient) temperatures. The rate of respiration was higher at the start of the experiment and gradually declined as the storage period prolonged, before becoming almost constant. The steady...
متن کاملElectrocatalytic Activity of the Ni57.3Co42.7 Alloy for the Hydrogen Evolution
The hydrogen evolution reaction (HER) on Ni57.3Co42.7 alloy and its main components, polycrystalline nickel and cobalt was investigated in 1.0 mol L–1 NaOH solution at 20 °C using cyclic voltammetry, pseudo-steady-state linear polarization and electrochemical impedance spectroscopy methods. The purpose of investigation was to evaluate the effect of cobalt on the intrinsic catalytic activity of ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical biochemistry
دوره 63 2 شماره
صفحات -
تاریخ انتشار 1975