Accuracy of real-time ultrasound measurements of total tissue, fat, and muscle depths at different measuring sites in lamb.

نویسندگان

  • M Thériault
  • C Pomar
  • F W Castonguay
چکیده

Accuracy of live ultrasound measurements to evaluate the total tissue depth (GR), as well as fat and LM depths at different scanning sites, was studied in 96 purebred Suffolk and Dorset lambs of both sexes slaughtered between 36 and 54 kg of BW. Before slaughter, 7 real-time ultrasound measurements were taken on lambs: fat and LM depths between the 12th and 13th ribs (transverse) and between the 3rd and 4th lumbar vertebrae (transverse and longitudinal), and GR. After slaughter, the measurements equivalent to ultrasound measurements were taken on digitized images of the cuts on the left half carcass of each lamb. Ultrasound GR and fat depth measurements were closely correlated with the corresponding carcass measurements (0.76 < or = r < or = 0.81). Ultrasound GR measurement exhibited a large error of central tendency, but the level of error due to the disturbance (ED) was comparable with fat depth measurements (ED = 8.5%; residual SD = 2.24 mm; CV of residuals = 9.5%). Ultrasound fat depth measurements were more accurate between the 12th and 13th ribs (error due to regression = 1.20; ED = 0.82) than between the 3rd and 4th lumbar vertebrae (error due to regression = 5.58 and 5.4; ED = 1.10 and 0.93, transverse and longitudinal, respectively), mainly due to image interpretation errors in the lumbar region. Measurements of LM depth demonstrated low variability in the population under study (SD = 2.6 mm), and these ultrasound measurements showed low correlation with the corresponding carcass measurements (0.34 < or = r < or = 0.43). The results of this study demonstrated that ultrasound measurements were more accurate for evaluating fat depth and the GR measurements than for estimating LM depths. Ultrasound GR measurement is a promising measurement, especially where carcass grading systems are based on this carcass measurement.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Live animal measurement of carcass traits by ultrasound: assessment and accuracy of sonographers.

The establishment and evaluation of an assessment system to accredit sonographers for measuring the carcass traits of subcutaneous fat depths and longissimus muscle area (LMA) on potential breeding animals by real-time ultrasound is described. Repeatability of operators, variation between the animal's left and right sides, and variations in technique were assessed from measurements and repeat m...

متن کامل

Estimation of Lamb Carcass Composition Using Real-time Ultrasound

Real-time ultrasound measurements (Falco 100 device, linear probe 3.5 MHz) were used to estimate in vivo carcass composition of Hungarian Merino (n=9) and British Milksheep (n=10) ram-lambs. Animals aged 110-120 days and were growing 29.73+/-1.11 kg and 28.98+/--0.95 kg, resp. There were little between-breed differences in the ultrasound records for subcutaneous fat thickness (0.33+/-0.10 cm; 0...

متن کامل

Estimation of carcass composition by ultrasound measurements in 4 anatomical locations of 3 commercial categories of lamb.

The objectives were to study the relationship between in vivo ultrasound measurements and cold carcass measurements at 4 anatomical points along the backbone of lambs and to determine appropriate regression equations to estimate carcass composition by using ultrasonic measurements at each anatomical point. The lambs (n = 114) used were suckling lambs (BW = 11.09 kg), light lambs (BW = 22.43 kg)...

متن کامل

The application of discriminant analysis in differentiation of fibroadenoma and ductal carcinoma of breast tissue using ultrasound velocity measurement

Background: Ultrasound propagation velocity was measured experimentally in normal, fibroadenoma and ductal carcinoma breast tissues, in order to distinguish normal breast tissue from tumors. Materials and methods: In quantitative measurements of ultrasound velocity, 403 breast tissue images were selected, comprising 130 normal breast tissue, 130 fibroadenoma, and 143 ductal carcinoma tumors. Th...

متن کامل

Evaluation of the use of gold nanoparticle as contrast agent in electrical impedance imaging

Introduction: Electrical Impedance Tomography (EIT) is a real time and minimal invasive imaging modality for detection of lesions in tissues even when their structures show no changes. Early detection of lesion with EIT depends on difference between electrical impedance of targeted tissue and its surroundings. Therefore, finding a contrast agent for EIT that increase this diffe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of animal science

دوره 87 5  شماره 

صفحات  -

تاریخ انتشار 2009