Inhibition of neointima formation by tranilast in pig coronary arteries after balloon angioplasty and stent implantation.

نویسندگان

  • S Ishiwata
  • S Verheye
  • K A Robinson
  • M Y Salame
  • H de Leon
  • S B King
  • N A Chronos
چکیده

OBJECTIVES We evaluated the effect of orally administered tranilast, N-(3,4-dimethoxycinnamoyl) anthranilic acid, on histologic and histomorphometric changes after angioplasty or stent implantation in pig coronary arteries. BACKGROUND Tranilast, which has antikeloid and antiallergic properties and therefore may modulate the fibrotic and inflammatory tissue responses to angioplasty and stenting, has been shown to inhibit angiographic restenosis in small clinical trials. However, its effect on histomorphometric changes in coronary arteries after angioplasty and stenting is unknown. METHODS Following initial pharmacokinetic studies in two pigs to determine desirable plasma levels of orally administered tranilast, 36 crossbred juvenile pigs were randomized to placebo or tranilast before undergoing balloon angioplasty in both the left anterior descending and left circumflex plus stent implantation in the right coronary artery. Oral tranilast was administered at 3 g/day starting 3 days before coronary injury and continued for 28 days until euthanasia. Injured vessels were harvested and sections analyzed by computer-assisted microscopic planimetry. RESULTS In balloon-injured vessels, tranilast was associated with a 37% reduction in neointimal area normalized to fracture length (0.47 +/- 0.01 vs. 0.74 +/- 0.03 mm; p < 0.001) and a 23% reduction in adventitial area normalized to vessel size (0.43 +/- 0.02 vs. 0.56 +/- 0.03; p = 0.003). In stented arteries, neointimal area normalized to injury score was 32% lower in the tranilast-treated group compared to control (1.94 +/- 0.17 vs. 2.86 +/- 0.29; p = 0.01). CONCLUSIONS In pig coronary arteries, tranilast was associated with a reduction in neointima formation and adventitial reaction after balloon injury. In stented vessels, tranilast was associated with a reduction in neointima formation normalized to injury score.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Response of very small (2 mm) porcine coronary arteries to balloon angioplasty and stent implantation.

OBJECTIVE To investigate the response of very small coronary arteries to stent deployment and balloon angioplasty. SETTING Normal porcine coronary arteries. METHODS 24 pigs underwent intervention to two main coronary arteries, in segments 2.0 mm in diameter, with balloons whose diameter was 2.5 mm at standard pressure. Twelve arteries received a BiodivYsio small vessel (SV) stent; 12 an NIR...

متن کامل

Different inflammatory response and oxidative stress in neointimal hyperplasia after balloon angioplasty and stent implantation in cholesterol-fed rabbits.

Inflammatory responses appear to play an important role in the occurrence of restenosis following coronary intervention. However, the contribution of C-reactive protein (CRP) and oxidative stress to restenosis after balloon angioplasty and stent implantation remains unclear. The aim of this study was to examine this issue using hyperlipidemic rabbits. Rabbits were divided into two groups; they ...

متن کامل

Intracoronary -Radiation Exacerbates Long-Term Neointima Formation in Balloon-Injured Pig Coronary Arteries

Background—Long-term biological effects of ionizing radiation on coronary arteries remain poorly defined. We examined late arterial responses 6 months after balloon angioplasty and -radiation in normal pig coronary arteries. Methods and Results—Coronary arteries of 25 adult pigs were randomized to receive 20 Gy (n 8) or 30 Gy (n 9) of Re -radiation or sham radiation (n 8) immediately after ball...

متن کامل

Intracoronary beta-radiation exacerbates long-term neointima formation in balloon-injured pig coronary arteries.

BACKGROUND Long-term biological effects of ionizing radiation on coronary arteries remain poorly defined. We examined late arterial responses 6 months after balloon angioplasty and beta-radiation in normal pig coronary arteries. METHODS AND RESULTS Coronary arteries of 25 adult pigs were randomized to receive 20 Gy (n=8) or 30 Gy (n=9) of (186)Re beta-radiation or sham radiation (n=8) immedia...

متن کامل

Effects of an Alpha-4 Integrin Inhibitor on Restenosis in a New Porcine Model Combining Endothelial Denudation and Stent Placement

Restenosis remains the main complication of balloon angioplasty and/or stent implantation. Preclinical testing of new pharmacologic agents preventing restenosis largely rely on porcine models, where restenosis is assessed after endothelial abrasion of the arterial wall or stent implantation. We combined endothelial cell denudation and implantation of stents to develop a new clinically relevant ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 35 5  شماره 

صفحات  -

تاریخ انتشار 2000