A compact PET detector module using SiPMs and MVT digitizers
نویسندگان
چکیده
Huazhong University of Science & Technology, Hubei, China Nowadays the simultaneous PET/MRI is being paid more and more attentions. Since MRI provides a high resolution, unsurpassed soft tissue contrast imaging and PET reveal the metabolism progress in molecular level, it is reasonable to believe the PET/ MRI will be a powerful tool to improve the understanding of pathogenesis and mechanism of brain disease. Such a simultaneous system can be implemented by integrating the RF coil with a PET scanner or inserting the PET scanner inside a MRI. In these solutions, one of the challenges is to develop compact and magnetic field compatible PET detectors. Thanks to the SiPMs, such detectors now are realizable. Aim for the simultaneous PET/MRI system, we have developed a compact PET detector module by using of the SiPMs and MVT digitizers. In the module, output signals from the LYSO/SiPM detector blocks are sampled by the MVT digitizers and then sent out via the Ethernet communicator. The timing, energy and position information will be picked up by digitally analyzing the resulted samples in a PC. In the LYSO/SiPM detector blocks, we use cross-wire method to readout the signals from SiPMs and further using transmission-line method to multiplex the signals. In this way, we get a 36:4 readout channel reducing. In this work, we have setup a dual-panel coincidence detection and imaging system by using a pair of the detector modules. The timing and energy resolution of the system are measured to be 1.67nS FWMH and 16.8% @511keV, respectively. With the system, we also obtained the imaging of a homemade mirco-Derenzo phantom which successfully resolved the 1.6 mm hollows. In future, we will investigate the feasibility of building a simultaneous PET/MRI system by using these modules.
منابع مشابه
Development of an MR-compatible DOI-PET detector module
Department of Electrical Engineering, Tsinghua University, Beijing, China Silicon Photomultiplier (SiPM) is a promising sensor for MR-compatible PET systems. In this paper, we developed a compact 2-layer DOI-PET detector. The top layer is a 15Ã15 LYSO array, and the crystal size is 2x2x7mm. The bottom layer is a 16Ã16 array with the same size crystals. There is half-crystal offset between two l...
متن کاملA large area, silicon photomultiplier-based PET detector module.
The introduction of silicon photomultipliers (SiPM) has facilitated construction of compact, efficient and magnetic field-hardened positron emission tomography (PET) scanners. To take full advantage of these devices, methods for using them to produce large field-of-view PET scanners are needed. In this investigation, we explored techniques to combine two SiPM arrays to form the building block f...
متن کاملA PET detector prototype based on digital SiPMs and GAGG scintillators.
Silicon Photomultipliers (SiPM) are interesting light sensors for Positron Emission Tomography (PET). The detector signal of analog SiPMs is the total charge of all fired cells. Energy and time information have to be determined with dedicated readout electronics. Philips Digital Photon Counting has developed a SiPM with added electronics on cell level delivering a digital value of the time stam...
متن کاملProgress report on the MindView brain PET detector module based on large area SiPMs arrays
Institute for Instrumentation in Molecular Imaging, CSIC-UPV, Valencia, Spain The main technical goal of the MindView project and, thus, the subject of this contribution, is achieving simultaneous PET/MR imaging, dedicated to brain examination in clinical research settings to study psychiatric disorders. The system will allow visualization of the relevant structures in the brain with very high ...
متن کاملPhoto-Detectors for Time of Flight Positron Emission Tomography (ToF-PET)
We present the most recent advances in photo-detector design employed in time of flight positron emission tomography (ToF-PET). PET is a molecular imaging modality that collects pairs of coincident (temporally correlated) annihilation photons emitted from the patient body. The annihilation photon detector typically comprises a scintillation crystal coupled to a fast photo-detector. ToF informat...