The Chemical Properties of Air-water Discharge Induced by Double Die- lectric Barrier Discharge

نویسندگان

  • Liu Kun
  • He Wei
چکیده

A set of air-water discharge induced by double DBD device has been designed to obtain hydrogen peroxide (H2O2) and ozone (O3) levels, simultaneously. How the H2O2 and O3 are being produced, which have extensively been studied by different experimental approaches such as air cooling, atomization amount, voltage applied, pH value and electrical conductivity (EC). The experimental results show that with the increase of atomization amount, O3 output reduced slightly, while in the start H2O2 output increased that later decreased. On applying high voltages, O3 output raised from 26kV to 32kV, which later decreased from 32kV to 34kV, in addition a constant increase trend seen in H2O2 output under like voltage conditions. EC also induced a gradual ascend in H2O2 output , while descends O3 output in first instance at EC level 0 to 2500μs but later remained stationary at higher EC levels (2500 to 10000μs). Like many other factors, similar pattern seen while studying pH effects which initially boost and later decrease in the H2O2 output but two inflection points for O3 output. It is concluded for the results that, H2O2 and O3 output can reasonably be controlled under different physico-chemical conditions, hence to attain the desired results with potential usage in chemical pollution, material handling, biomedicine and lot more etc.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multi-objective optimization and analysis of electrical discharge machining process during micro-hole machining of D3 die steel employing salt mixed de-ionized water dielectric

Correct selection of manufacturing condition is one of the most important aspects which should be considered in the majority of manufacturing processes,  particularly in the process related to advanced machining process like electrical discharge machining. In electrical discharge machining (EDM), dielectric fluid plays an important role since machining characteristics are greatly influenced by ...

متن کامل

A New Approach to Provide High Water Permeable Polyethersulfone based Nanofiltration Membrane by Air Plasma Treatment

In this study, polyethersulfone based nanofiltration membranes were modified by air plasma generated through dielectric barrier discharge to increase the membrane hydrophilicity aiming to improve the separation and antifouling characteristics. The effect of plasma time on the physico-chemical and separation properties of membrane was investigated. The PES nanofiltration membranes were fabricate...

متن کامل

Studying lithium-ion battery packs cooling system using water-nanofluids composition

In this study, the Li-ion batteries temperature increase during the discharge process was measured empirically and evaluated using numerical simulation. Moreover, the battery packs cooling using the water, air and water-nano composition fluids such as water-alumina, water-copper oxide, and water-gold was studied through numerical simulation. Accordingly, the battery cooling was simulated by CFD...

متن کامل

Modification of activated carbon by cold plasma and its effect on the adsorption of toluene

Abstract Background and aims: Clean air is one of the basic needs for human health and well-being. However, along with economic growth and development, transportation, urbanization and energy consumption have also risen and provide many concerns such as air pollution, which require urgent and wide attention. Air pollution in the worldwide is considered as a risk factor for human health and one...

متن کامل

Experimental investigation of a solar desalination performance based on humidification-dehumidification technique with air and water closed cycle

In this study, the performance of solar desalination by humidification-dehumidification of closed air and water in Ahvaz city was investigated. This desalination includes a collector, condenser, salty water, freshwater tanks, air blower, and water pump. The evaluation of the system was done at three levels of air velocity (3, 4, and 5 m/s) and at three pump discharge levels (2, 4, and 6 liters/...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015