Reliability of VEP Recordings Using Chronically Implanted Screw Electrodes in Mice.

نویسندگان

  • Kalina Makowiecki
  • Andrew Garrett
  • Vince Clark
  • Stuart L Graham
  • Jennifer Rodger
چکیده

PURPOSE Visual evoked potentials (VEPs) are widely used to objectively assess visual system function in animal models of ophthalmological diseases. Although use of chronically implanted electrodes is common in longitudinal VEP studies using rodent models, reliability of recordings over time has not been assessed. We compared VEPs 1 and 7 days after electrode implantation in the adult mouse. We also examined stimulus-independent changes over time, by assessing electroencephalogram (EEG) power and approximate entropy of the EEG signal. METHODS Stainless steel screws (600-μm diameter) were implanted into the skull overlying the right visual cortex and the orbitofrontal cortex of adult mice (C57Bl/6J, n = 7). Animals were reanesthetized 1 and 7 days after implantation to record VEP responses (flashed gratings) and EEG activity. Brain sections were stained for glial activation (GFAP) and cell death (TUNEL). RESULTS Reliability analysis, using intraclass correlation coefficients, showed VEP recordings had high reliability within the same session, regardless of time after electrode implantation and peak latencies and approximate entropy of the EEG did not change significantly with time. However, there was poorer reliability between recordings obtained on different days, and a significant decrease in VEP amplitudes and EEG power. This amplitude decrease could be normalized by scaling to EEG power (within-subjects). Furthermore, glial activation was present at both time points but there was no evidence of cell death. CONCLUSIONS These results indicate that VEP responses can be reliably recorded even after a relatively short recovery period but decrease response peak amplitude over time. Although scaling the VEP trace to EEG power normalized this decrease, our results highlight that time-dependent cortical excitability changes are an important consideration in longitudinal VEP studies. TRANSLATIONAL RELEVANCE This study shows changes in VEP characteristics over time in chronically implanted mice. Thus, future preclinical longitudinal studies should consider time in addition to amplitude and latency when designing and interpreting research.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sensory interaction in the superior colliculus of freely moving rat indicated by evoked potentials.

Sensory monomodal and bimodal interaction was compared in the anterior medial superior colliculus (CS) of freely moving Long-Evans rats with chronically implanted electrodes using pairs of click and flash stimuli separated by intervals of 100 ms. The amplitudes and peak times of first and second evoked potentials were statistically evaluated and compared with the uninfluenced control values of ...

متن کامل

Flexible polyimide microelectrode array for in vivo recordings and current source density analysis.

This work presents implantable, flexible polymer-based probes with embedded microelectrodes for acute and chronic neural recordings in vivo, as tested on rodents. Acute recordings using this array were done in mice under urethane anesthesia and compared to those made using silicon-based probes manufactured at the Center for Neural Communication Technology, University of Michigan. The two electr...

متن کامل

Conscious Wireless Electroretinogram and Visual Evoked Potentials in Rats

The electroretinogram (ERG, retina) and visual evoked potential (VEP, brain) are widely used in vivo tools assaying the integrity of the visual pathway. Current recordings in preclinical models are conducted under anesthesia, which alters neural physiology and contaminates responses. We describe a conscious wireless ERG and VEP recording platform in rats. Using a novel surgical technique to chr...

متن کامل

A screw microdrive for adjustable chronic unit recording in monkeys.

A screw microdrive is described that attaches to the grid system used for recording single neurons from brains of awake behaving monkeys. Multiple screwdrives can be mounted on a grid over a single cranial opening. This method allows many electrodes to be implanted chronically in the brain and adjusted as needed to maintain isolation. rights reserved.

متن کامل

Long-term spinal reflex studies in awake behaving mice.

The increasing availability of genetic variants of mice has facilitated studies of the roles of specific molecules in specific behaviors. The contributions of such studies could be strengthened and extended by correlation with detailed information on the patterns of motor commands throughout the course of specific behaviors in freely moving animals. Previously reported methodologies for long-te...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Translational vision science & technology

دوره 4 2  شماره 

صفحات  -

تاریخ انتشار 2015