A monitoring device for pressurised-air-driven diaphragm-based artificial heart assist devices.

نویسندگان

  • F P Hoeben
  • F F de Mul
  • H S Stokkink
  • M H Koelink
  • J Greve
چکیده

A non-invasive device has been developed to monitor the diaphragm position and the blood flow in artificial heart assist devices equipped with a pressurised-air-driven diaphragm. Light scattering from the diaphragm is used as a mechanism for measuring. Information about the position of several points of the diaphragm can be obtained. The completely empty or filled situation can be detected and used for control purposes. Flow data can be extracted and bending characteristics of the diaphragm during operation can be studied.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design an Equivalent Left Ventricular Assist Device for Medical Equipment Labs

LVAD is a mechanical pump supporting a weak heart function and blood flow. Sometimes, the heart may not recover fast enough to take over the pumping action immediately after surgery, in such patients a temporary support device has been employed to maintain the pumping action until the patient’s own heart recovers. This device can be considered as a temporary alternative before the process of ar...

متن کامل

Improvement of Left Ventricular Assist Device (LVAD) in Artificial Heart Using Particle Swarm Optimization

In this approach, the Left ventricular assist pump for patients with left ventricular failure isused. The failure of the left ventricle is the most common heart disease during these days. Inthis article, a State feedback controller method is used to optimize the efficiency of a samplingpump current. Particle Swarm Algorithm, which is a set of rules to update the position andvelocity, is applied...

متن کامل

Mechanical evaluation of the diaphragm in pneumatically-driven left ventricular assist devices by FEM analysis

Pneumatically-driven left ventricular assist devices (LVADs) are widely used because they are lower in cost and simpler in operability in comparison with mechanically-driven devices. However, some problems such as the damage of their diaphragms in the devices have been pointed out. In this study, an evaluation program including FEM analysis, in which the NIPRO-LVAD is selected as a sample of a ...

متن کامل

Application of Acoustic Spectral Analysis Technique for In-service Detection of Pump Diaphragm Failure

The main component of air-driven pumps are elastic diaphragms. These diaphragms are made from rubber or some other flexible material such as a thermoplastic elastomer. A method based on frequency analysis of the acoustic signal obtained from an air-driven pump during operation is described in this paper. A fully digital system for frequency analysis based on a personal computer was developed fo...

متن کامل

Diaphragm motion affects flow patterns in an artificial heart.

In the sac-driven artificial heart, the flow characteristics are coupled to the dynamics of the sac motion. The opening dynamics of the sac wall can, for example, strongly affect the chamber flow characteristics during diastole by directing or impeding the inflow. Poor sac motion can reduce the volume output of the pump and may increase the potential for thrombus formation within the ventricula...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics

دوره 13 2  شماره 

صفحات  -

تاریخ انتشار 1992