Variability of wavefront aberration measurements in small pupil sizes using a clinical Shack-Hartmann aberrometer

نویسندگان

  • Harilaos S Ginis
  • Sotiris Plainis
  • Aristophanis Pallikaris
چکیده

BACKGROUND Recently, instruments for the measurement of wavefront aberration in the living human eye have been widely available for clinical applications. Despite the extensive background experience on wavefront sensing for research purposes, the information derived from such instrumentation in a clinical setting should not be considered a priori precise. We report on the variability of such an instrument at two different pupil sizes. METHODS A clinical aberrometer (COAS Wavefront Scienses, Ltd) based on the Shack-Hartmann principle was employed in this study. Fifty consecutive measurements were performed on each right eye of four subjects. We compared the variance of individual Zernike expansion coefficients as determined by the aberrometer with the variance of coefficients calculated using a mathematical method for scaling the expansion coefficients to reconstruct wavefront aberration for a reduced-size pupil. RESULTS Wavefront aberration exhibits a marked variance of the order of 0.45 microns near the edge of the pupil whereas the central part appears to be measured more consistently. Dispersion of Zernike expansion coefficients was lower when calculated by the scaling method for a pupil diameter of 3 mm as compared to the one introduced when only the central 3 mm of the Shack - Hartmann image was evaluated. Signal-to-noise ratio was lower for higher order aberrations than for low order coefficients corresponding to the sphero-cylindrical error. For each subject a number of Zernike expansion coefficients was below noise level and should not be considered trustworthy. CONCLUSION Wavefront aberration data used in clinical care should not be extracted from a single measurement, which represents only a static snapshot of a dynamically changing aberration pattern. This observation must be taken into account in order to prevent ambiguous conclusions in clinical practice and especially in refractive surgery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design and validation of a scanning Shack Hartmann aberrometer for measurements of the eye over a wide field of view

Peripheral vision and off-axis aberrations not only play an important role in daily visual tasks but may also influence eye growth and refractive development. Thus it is important to measure off-axis wavefront aberrations of human eyes objectively. To achieve efficient measurement, we incorporated a double-pass scanning system with a Shack Hartmann wavefront sensor (SHWS) to develop a scanning ...

متن کامل

The contribution of the fixational eye movements to the variability of the measured ocular aberration.

The purpose of this work is to analyze the contribution of eye movements to the variability of the Zernike coefficients as determined with a Hartmann-Shack aberrometer. In order to isolate this effect we considered static aberrations tied to the eye pupil. We used several eye movements of different magnitude, both synthetic and corresponding to actual series recorded in our laboratory with diff...

متن کامل

Early clinical outcomes of wavefront-guided myopic LASIK treatments using a new-generation hartmann-shack aberrometer.

PURPOSE To provide an initial retrospective evaluation of early postoperative outcomes after wavefront-guided myopic LASIK using a new-generation Hartmann-Shack wavefront sensor. METHODS A noncomparative, retrospective study of 243 eyes of 126 patients that underwent primary wavefront-guided LASIK, using wavefront data obtained with a new Hartmann-Shack aberrometer (iDesign Advanced WaveScan ...

متن کامل

Wavefront-Guided Photorefractive Keratectomy with the Use of a New Hartmann-Shack Aberrometer in Patients with Myopia and Compound Myopic Astigmatism

Purpose. To assess refractive and visual outcomes and patient satisfaction of wavefront-guided photorefractive keratectomy (PRK) in eyes with myopia and compound myopic astigmatism, with the ablation profile derived from a new Hartmann-Shack aberrometer. Methods. In this retrospective study, 662 eyes that underwent wavefront-guided PRK with a treatment profile derived from a new generation Hart...

متن کامل

A Limitation of Hartmann-Shack System in Measuring Wavefront Aberrations for Patients Received Laser Refractive Surgery

PURPOSE To explore the relationship between ablation parameters of myopic laser surgery and measurement area of wavefront aberration (WA) with Hartmann-Shack wavefront sensor. METHODS 58 subjects undergone myopic laser surgeries and 74 uncorrected myopic subjects were enrolled in this experiment. The laser ablation parameters were obtained from surgical records, which included spherical error...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • BMC Ophthalmology

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2004