Assessment of low-frequency fatigue with two methods of electrical stimulation.
نویسندگان
چکیده
The aim of this study was to compare the use of transcutaneous vs. motor nerve stimulation in the evaluation of low-frequency fatigue. Nine female and eleven male subjects, all physically active, performed a 30-min downhill run on a motorized treadmill. Knee extensor muscle contractile characteristics were measured before, immediately after (Post), and 30 min after the fatiguing exercise (Post30) by using single twitches and 0.5-s tetani at 20 Hz (P20) and 80 Hz (P80). The P20-to-P80 ratio was calculated. Electrical stimulations were randomly applied either maximally to the femoral nerve or via large surface electrodes (ES) at an intensity sufficient to evoke 50% of maximal voluntary contraction (MVC) during a 80-Hz tetanus. Voluntary activation level was also determined during isometric MVC by the twitch-interpolation technique. Knee extensor MVC and voluntary activation level decreased at all points in time postexercise (P < 0.001). P20 and P80 displayed significant time x gender x stimulation method interactions (P < 0.05 and P < 0.001, respectively). Both stimulation methods detected significant torque reductions at Post and Post30. Overall, ES tended to detect a greater impairment at Post in male and a lesser one in female subjects at both Post and Post30. Interestingly, the P20-P80 ratio relative decrease did not differ between the two methods of stimulation. The low-to-high frequency ratio only demonstrated a significant time effect (P < 0.001). It can be concluded that low-frequency fatigue due to eccentric exercise appears to be accurately assessable by ES.
منابع مشابه
Interaction of Sodium Valproate With Low-Frequency Electrical Stimulation During Kindling
Background: The interaction between antiepileptic drugs and brain electrical stimulation is a potential therapy to control of seizures in patient with pharmacoresistance to drugs. So, the aim of present study was designed to determine the effect of a sub effective dose of sodium valproate combined with low-frequency electrical stimulation during kindling. Material and Methods: One tripolar ele...
متن کاملThe effect of parameters of low-frequency electrical stimulation on piriform-cortex kindled seizures in rat
Introduction: Electrical low-frequency stimulation (LFS) has antiepileptic effect, but the role of different stimulation parameters on this effect has not been determined. In this study the effect of different LFS parameters (intensity, pulse duration and train duration) on piriform-cortex kindled seizures was investigated. Methods: Seizure was produced in animals using kindling model of ep...
متن کاملControl of epileptic seizures by electrical low frequency deep brain stimulation: A review of probable mechanisms
Epilepsy is the most common neurological disease with no definitive method in treatment. Notably, the main way to treat and control epileptic seizures is drug therapy. However, about 20-30% of patients with epilepsy are drug resistant and require other therapeutic manners. Deep brain stimulation is a new therapeutic strategy for these patients. Conspicuously, there are no clear answers for basi...
متن کاملThe Effect of Sodium Valproate and Low Frequency Electrical Stimulation on Motor Activity During Rapid Kindling of Hippocampal CA1 Region in Adult Male Rat: An Experimental Study
Background and Objectives: Epilepsy is a chronic neurological disorder that requires long treatment with less side effects. Therefore, this study aimed to determine the effect of sodium valproate and electrical stimulation of the brain with low frequency (LFS) on the motor activity of male rat during hippocampus rapid kindling. Material and Methods: In this experimental study, 56 male adult ra...
متن کاملOptimized design and implementation of electrical stimuli to reduce muscle pain and treat osteoarthritis
Today, electrical stimulation as a treatment method by creating muscle contraction by creating internal electrical stimulation is a method to reduce muscle pain. In addition, it is used to treat osteoarthritis. The aim of this study was to study, design and implement optimized hardware for electrical muscle stimulators to reduce pain and treat osteoarthritis. Here, the design of the optimal sys...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of applied physiology
دوره 97 5 شماره
صفحات -
تاریخ انتشار 2004