An assessment of the Roche Amplicor Chlamydia trachomatis/Neisseria gonorrhoeae multiplex PCR assay in routine diagnostic use on a variety of specimen types.

نویسندگان

  • David E Leslie
  • Franca Azzato
  • Norbert Ryan
  • Janet Fyfe
چکیده

The Roche Cobas Amplicor Chlamydia trachomatis/Neisseria gonorrhoeae polymerase chain reaction (PCR) assay can simultaneously detect both C. trachomatis and N. gonorrhoeae, and has been cleared by United States Food and Drug Administration (FDA) for the testing of endocervical and urethral swabs and urine specimens. The Amplicor N. gonorrhoeae PCR target sequence is known to be present in some strains of commensal Neisseria species, including N. cinerea and N. subflava, necessitating the use of a second PCR assay to confirm positive results. This study analyses the performance of the assay on 7,007 unselected specimens submitted to the laboratory for the PCR diagnosis of N. gonorrhoeae and C. trachomatis; compares the PCR assay with culture for the detection of N. gonorrhoeae; examines the performance of the assay with specimens from different body sites; and briefly compares two confirmatory PCR assays. Confirmation rates for an initial Amplicor N. gonorrhoeae positive result varied widely by specimen type, ranging from 86.2 per cent for penile/urethral swabs to 5.6 per cent for oropharyngeal swabs, indicating all positive Amplicor N. gonorrhoeae results should be confirmed by a second method to maintain adequate specificity. Overall there was 98.1 per cent agreement between the confirmed PCR assay and culture, with confirmed PCR showing a sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of 81.7 per cent, 99.5 per cent, 92.7 per cent and 98.5 per cent respectively, compared with N. gonorrhoeae culture. When confirmed C. trachomatis/N. gonorrhoeae PCR assay performance was analysed against culture using only FDA-cleared specimens (553 penile/ urethral swabs, urines and cervical/vaginal swabs), sensitivity, specificity, PPV and NPV and percent agreement were 96.7 per cent, 99.8 per cent, 98.9 per cent, 99.4 per cent and 99.3 per cent respectively. No significant differences were found between the two confirmatory PCR assays used during the study period. Limitations of Amplicor for the detection of N. gonorrhoeae and the appropriate use of combined C. trachomatis/N. gonorrhoeae PCR in a routine diagnostic setting are discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diagnostic performance of the Roche AMPLICOR PCR in detecting Neisseria gonorrhoeae in genitourinary specimens from female sex workers in Cotonou, Benin.

The objective of this study was to evaluate the diagnostic performance of the Roche multiplex AMPLICOR Chlamydia trachomatis/Neisseria gonorrhoeae PCR test for the detection of Neisseria gonorrhoeae infection in female urine specimens and wet and dry endocervical swabs. Endocervical swabs and urine specimens were collected from 342 female sex workers from Cotonou, Benin, and were tested using t...

متن کامل

Comparison between the LCx Probe system and the COBAS AMPLICOR system for detection of Chlamydia trachomatis and Neisseria gonorrhoeae infections in patients attending a clinic for treatment of sexually transmitted diseases in Amsterdam, The Netherlands.

Two assays for the detection of Chlamydia trachomatis and Neisseria gonorrhoeae were compared: the LCx Probe system (the LCx system; Abbott Diagnostic Laboratories, North Chicago, Ill.) and the COBAS AMPLICOR C. trachomatis/N. gonorrhoeae system (the COBAS AMPLICOR system; Roche Diagnostic Systems, Branchburg, N.J.). Endocervical swab specimens, male urethral swab specimens, and female and male...

متن کامل

Evaluation of automated COBAS AMPLICOR PCR system for detection of several infectious agents and its impact on laboratory management.

We evaluated the COBAS AMPLICOR (CA) PCR system (Roche Diagnostic Systems) designed for automated PCR amplification and detection of nucleic acids from infectious agents in clinical samples. The Roche AMPLICOR microwell plate (MWP) PCR was the reference method. CA amplifies target nucleic acid, captures the biotinylated amplification products by using magnetic particles coated with specific oli...

متن کامل

Evaluation of conventional and real-time PCR assays using two targets for confirmation of results of the COBAS AMPLICOR Chlamydia trachomatis/Neisseria gonorrhoeae test for detection of Neisseria gonorrhoeae in clinical samples.

Two conventional PCR-enzyme immunoassays (PCR-EIAs) and two real-time PCR assays (LightCycler system; Roche Diagnostics) were evaluated as confirmation assays with cppB and 16S rRNA genes as targets. Of 765 male and female genitourinary and nasopharyngeal specimens positive for Neisseria gonorrhoeae in the COBAS AMPLICOR Chlamydia trachomatis/Neisseria gonorrhoeae PCR test (Roche Diagnostics), ...

متن کامل

Validation of a laboratory-developed real-time PCR protocol for detection of Chlamydia trachomatis and Neisseria gonorrhoeae in urine.

OBJECTIVE To evaluate a sensitive and specific, real-time PCR assay with internal control for Chlamydia trachomatis and Neisseria gonorrhoeae DNA detection in urine specimens. METHODS The diagnostic performance of a laboratory-developed quadruplex assay (LDQA) targeting the cryptic plasmid and MOMP genes of C trachomatis, the porA pseudogene of N gonorrhoeae and a synthetic internal control w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Communicable diseases intelligence quarterly report

دوره 27 3  شماره 

صفحات  -

تاریخ انتشار 2003