Clinical evaluation of the Sorin Xtra® autotransfusion system
نویسندگان
چکیده
The performance of the Sorin Xtra® Autotransfusion System (ATS) was studied in 62 patients undergoing coronary artery bypass grafting. Blood was collected intraoperatively and washed using three different wash sets in 4 groups. Both collected and washed blood were analysed for hemoglobin levels and hematocrit, concentrations of proteins, albumin, heparin and plasma free hemoglobin (PFH) were determined, erythrocytes, platelets and leukocytes were counted. Hematocrit measurements of the Xtra® were compared with laboratory measurements to study the accuracy of the Xtra® hematocrit sensor. In addition, the red blood cell recovery rate and elimination rates were calculated to evaluate the clinical performance of the Xtra®. The Xtra® ATS produced a volume of concentrated red blood cells with an average hematocrit from 58% to 63%, depending on the size of the bowl and the chosen default program. In all bowl sizes and programs, the Xtra® Hct-out measurement underestimated the CELL-DYN measurement by approximately 15%. The calculated recovery rates for red blood cells (RBC) in the 4 groups ranged from 86.7% to 91.6%. Elimination rates were calculated in each group for proteins (96.8-99.2%), albumin (96.4-98.7%), plasma free hemoglobin (83.6-91.2%), heparin (98.8-99.9%), platelets (82.4-94.3%) and white blood cells (28.6-42.3%). The Xtra® ATS can be appealing for its performance by producing high hematocrit levels in the washed RBC volume, while keeping RBC recovery rate at the same high level (≈ 90%) as in its predecessor, the Electa® Autotransfusion System.
منابع مشابه
The impact of bowl size, program setup, and blood hematocrit on the performance of a discontinuous autotransfusion system.
BACKGROUND Cell salvage is an essential element in the concept of blood management. Modern devices provide different bowl sizes and sensor-directed programs to optimally adjust to varying clinical situations. STUDY DESIGN AND METHODS In an experimental performance study, the discontinuous autotransfusion device XTRA (LivaNova/Sorin) was evaluated using fresh donor blood anticoagulated with he...
متن کاملRemoval of hepatocarcinoma cells from blood via cell washing and filtration techniques.
Utilization of autotransfusion during tumor resection remains controversial due to viability of carcinoma cells remaining in collected blood. The purpose of this study was to evaluate autotransfusion techniques combined with leukocyte depleting filters (LDF) for removal of hepatocarcinoma cells from autotransfusate. An in vitro model was created by contaminating expired human erythrocytes with ...
متن کاملComparison of Efficacy and Safety of Two Different Enoxaparin Products in Prevention of Venous Thromboembolism Following Major Obstetric-gynecological Surgeries: An Open-label Randomized Clinical Trial
Venous thromboembolism (VTE) occurs in about 5 percent of patients undergoing major abdominal surgeries. Prophylaxis of VTE is recommended using unfractionated heparin (UF) or low molecular weight heparin (LMWH) in high-risk patients. In spite of advantages and confirmed cost-effectiveness of LMWH, high costs of enoxaparin branded preparations limit its use. We aimed to compare the efficacy and...
متن کاملA clinical review of autotransfusion and its role in trauma.
AUTOTRANSFUSION is defined as the collection and reinfusion of a patient's own blood. The first description of autotransfusion dates back to 1818, when Blundell1 used it in London to counter postpartum hemorrhage, with a mortality of 50%. Autotransfusion in the setting of chest trauma was first recorded by Elmendorf2 during battle in 1917 and in civilian life in 1931. The earliest reported Amer...
متن کاملComparison of Efficacy and Safety of Two Different Enoxaparin Products in Prevention of Venous Thromboembolism Following Major Obstetric-gynecological Surgeries: An Open-label Randomized Clinical Trial
Venous thromboembolism (VTE) occurs in about 5 percent of patients undergoing major abdominal surgeries. Prophylaxis of VTE is recommended using unfractionated heparin (UF) or low molecular weight heparin (LMWH) in high-risk patients. In spite of advantages and confirmed cost-effectiveness of LMWH, high costs of enoxaparin branded preparations limit its use. We aimed to compare the efficacy and...
متن کامل