[The impact of different antiepileptic drugs on the sedation of children during magnetic resonance imaging].

نویسندگان

  • Isil Davarci
  • Murat Karcioglu
  • Kasim Tuzcu
  • Fatmagul Basarslan
  • Ramazan Davran
  • Erhan Yengil
  • Cahide Yilmaz
  • Selim Turhanoglu
چکیده

BACKGROUND AND OBJECTIVES The induction and inhibition of cytochrome P450 isoenzymes by antiepileptic drugs lead to changes in the clearance of anesthetic drugs eliminated via hepatic metabolism. We investigated the duration of the sedation and additional anesthetic needs during magnetic resonance imaging in epileptic children receiving antiepileptic drugs that cause either enzyme induction or inhibition. METHODS In American Society of Anesthesiology I-II, 120 children aged 3-10 years were included. Group 1: children using antiepileptic drugs that cause cytochrome P450 enzyme induction; Group 2: those using antiepileptic drugs that cause inhibition; and Group 3: those that did not use antiepileptic drugs. Sedation was induced with the use of 0.05 mg kg(-1) midazolam and 1 mg kg(-1) propofol. An additional 0.05 mg kg(-1) of midazolam and rescue propofol (0.5 mg kg(-1)) were administered and repeated to maintain sedation. The duration of sedation and the additional sedation needed were compared. RESULTS The duration of the initial dose was significantly shorter in Group I compared with groups II and III (p = 0.001, p = 0.003, respectively). It was significantly longer in Group II compared with groups I and III (p = 0.001, p = 0.029, respectively). The additional midazolam needed for adequate sedation was increased in Group I when compared with groups II and III (p = 0.010, p = 0.001, respectively). In addition, the rescue propofol dose was significantly higher only in Group I when compared with Group III (p = 0.002). CONCLUSION In epileptic children, the response variability to the initial sedative agents during the magnetic resonance imaging procedure resulting from the inhibition or induction of the cytochrome P450 isoenzymes by the antiepileptic drugs mandated the titration of anesthetic agents.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cerebral Palsy and Patterns of Magnetic Resonance Imaging (MRI): A Review

Cerebral Palsy is the most common chronic motor disorder of childhood, that affecting approximately 3 infants per 1000 live-births. The risk of brain injuries that potentially cause Cerebral Palsy has amplified with increasing in survival rates for preterm infants. In addition Cerebral Palsy has a huge economic impact, to immeasurable health, social, and psychological problems that affected chi...

متن کامل

DNA Damages on Blood Cells After Cardiac Magnetic Resonance Imaging

Introduction: Along with the increased use of cardiac imaging at clinics there is increased attention to the potential risks related to the methods used like magnetic resonance (MR) and it cannot be ruled out that MR can alter DNA structure. The aim of this review is to assess the impact of routine cardiac magnetic resonance (CMR) scanning on DNA damages in human T lymphocytes....

متن کامل

ANALYTICAL STUDY OF EFFECT OF BILAYER INORGANIC AND ORGANIC COATING AROUND THE IRON OXIDE NANOPARTICLES ON MAGNETIC RESONANCE IMAGING CONTRAST

Background & Aims: In recent years, iron oxide nanoparticles have been used in contrast-enhanced magnetic resonance imaging for diagnosing a wide range of diseases. In order to provide biocompatibility and prevent the toxicity of the nanoparticles, using organic or inorganic coating around these nanoparticles is important for their application. The aim of this study is to investigate the effect...

متن کامل

ارزش تشخیصی تصویربرداری ام- آر اوروگرافی دینامیک در کودکان مبتلا به عفونت ادراری

Background: Urinary tract infection 0 in children causes renal scarring and permanent damage to the organ. In this study, we compared the diagnostic value of magnetic resonance urogram for urinary tract anomalies with other conventional imaging methods in children with UTI. Methods: In this case-control study, 190 children (mean age 3.23±3.59 yrs) with UTI were recruited from the Pedi...

متن کامل

Pseudo-CT Generation from Magnetic Resonance Imaging by fuzzy look up table algorithm

Introduction: Despite growing interest in the use of magnetic resonance imaging (MRI) in the external radiotherapy design process (RT), Computer Tomography (CT) remains a gold standard and is regarded as a basic imaging modality in radiotherapy. MRI shows the high contrast in soft tissues without any radiation exposure to patients. As a result, MRI is used in functional tissue ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Revista brasileira de anestesiologia

دوره 64 5  شماره 

صفحات  -

تاریخ انتشار 2014