Is the reciprocating movement per se able to improve the cyclic fatigue resistance of instruments?

نویسندگان

  • P Kiefner
  • M Ban
  • G De-Deus
چکیده

AIM To compare cyclic fatigue resistance of two geometrically similar nickel-titanium instruments, used in conditions similar to clinical use in reciprocating and continuous rotary motion. METHODOLOGY Four groups of eighteen instruments each, Reciproc(®) files sizes ISO 25 and 40 (R25 and R40) and Mtwo(®) files sizes ISO 25 and 40 (M25 and M40), were tested in reciprocating and continuous rotary motion, employing a novel experiment device. An artificial root canal (diameter, 1.4 mm; angle of curvature, 60 °; and curvature radius, 5 mm) was milled into a stainless steel block. To simulate clinical conditions, instead of rotating the file in static position, the set-up was designed to produce a continuous up-and-down pecking motion along the vertical axis of the instrument. Time to fracture (TTF) and push-pull cycles (PPC) were recorded, the number of cycles to fracture (NCF) was determined, and fractured instrument surfaces were examined under a scanning electron microscope (SEM). RESULTS Mean time to fracture was 34.44 ± 8.58 min for R25 in reciprocation motion, 35.77 ± 4.82 min for R40 in reciprocation motion, 12.15 ± 1.74 min for M25 in continuous rotary motion and 13.27 ± 2.02 min for M40 in continuous rotary motion, whereas 28.52 ± 3.27 min for R25 in continuous rotary motion, 23.87 ± 1.52 min for R40 in continuous rotary motion, 31.07 ± 1.79 min for M25 in reciprocation motion and 31.08 ± 3.26 min for M40 in reciprocation motion. There was a significant difference (P < 0.0001) for the cyclic fatigue resistance between the reciprocation motion and the continuous rotary motion groups. Reciproc(®) files in reciprocating movement had a significantly higher NCF than Mtwo(®) files, when used in continuous rotation. The highest resistance to failure was shown by Reciproc(®) files in reciprocation movement, followed by Mtwo(®) files in reciprocation and Reciproc(®) files in continuous motion. Mtwo(®) files in continuous rotary movement had the least resistance. SEM analysis of the fracture surface confirmed typical features of cyclic fatigue failure. CONCLUSION Reciprocating movement increased the cyclic fatigue resistance of NiTi instruments.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Extended cyclic fatigue life of F2 ProTaper instruments used in reciprocating movement.

AIM To evaluate the cyclic fatigue fracture resistance of engine-driven F2 ProTaper instruments under reciprocating movement. METHODOLOGY A sample of 30 NiTi ProTaper F2 instruments was used. An artificial canal was made from a stainless steel tube, allowing the instruments to rotate freely. During mechanical testing, different movement kinematics and speeds were used, which resulted in three...

متن کامل

Cyclic fatigue and torsional resistance of two new nickel-titanium instruments used in reciprocation motion: Reciproc versus WaveOne.

INTRODUCTION The use of reciprocating movement was claimed to increase the resistance of nickel-titanium (NiTi) file to fatigue in comparison with continuous rotation. Recently 2 new brands of NiTi files have been marketed for use in a RM mode. The purpose of this study was to compare the cyclic fatigue resistance and torsional resistance of these 2 files, Reciproc and WaveOne. METHODS Cyclic...

متن کامل

Comparison of cyclic fatigue and torsional resistance in reciprocating single-file systems and continuous rotary instrumentation systems.

As compared with continuous rotary systems, reciprocating motion is believed to increase the fatigue resistance of NiTi instruments. We compared the cyclic fatigue and torsional resistance of reciprocating single-file systems and continuous rotary instrumentation systems in simulated root canals. Eighty instruments from the ProTaper Universal, WaveOne, MTwo, and Reciproc systems (n = 20) were s...

متن کامل

Cyclic fatigue and torsional resistance of two new nickel - titanium instruments used in reciprocation motion : Reciproc Versus

The use of reciprocating movement (RM) was claimed to increase the resistance of nickel-titanium (NiTi) file to fatigue in comparison to continuous rotation (CR). Recently two new brands of NiTi file have been marketed for use in a RM mode. The purpose of this study was to compare the cyclic fatigue resistance and torsional resistance of these two files; Reciproc and WaveOne. Cyclic fatigue tes...

متن کامل

Effect of movement kinematics on the cyclic fatigue resistance of nickel-titanium instruments.

AIM To compare the cyclic fatigue resistance of new generation OneShape and WaveOne instruments when used with different kinematics. METHODOLOGY An artificial canal, made of stainless steel with an inner diameter of 1.5 mm, a 60° angle of curvature and a curvature radius of 3 mm, was used for cyclic fatigue test of new generation OneShape and WaveOne instruments. Groups were as follows (n = 2...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International endodontic journal

دوره 47 5  شماره 

صفحات  -

تاریخ انتشار 2014