A Legionnaires' disease outbreak: a water blaster and roof-collected rainwater systems.

نویسندگان

  • Greg Simmons
  • Sheryl Jury
  • Craig Thornley
  • David Harte
  • Jasmine Mohiuddin
  • Michael Taylor
چکیده

In February 2006, an outbreak of Legionnaires' disease (LD) was identified in Beachlands, a small, isolated east Auckland suburb. It was investigated through case finding, a case-control study, sampling potential sources of infection and by molecular typing (using sequence-based typing (SBT) of all Legionella pneumophila serogroup 1 (Lp1) isolates). Lp1 was isolated from the respiratory tract of one case, the roof-collected rainwater systems of five households (three associated with cases) and from a water blaster at a nearby marina. All isolates were indistinguishable, exhibiting the same SBT allele pattern. Three LD cases lived within 500m of the water blaster (the fourth case within 1250m) and downwind in prevailing conditions. Another domestic roof-collected rainwater supply contaminated by Lp1 (identical SBT pattern) was incidentally identified in another suburb 4km east of Beachlands. This is the first outbreak of LD linked to roof-collected rainwater supplies and the first isolation of Legionella from these systems in New Zealand. Aerosols containing Legionella discharged to air by the marina water blaster may have infected some cases directly or may have seeded roof-collected rainwater systems. Some cases may have been exposed by contaminated bathroom showers. Roof-collected rainwater systems need appropriate design, careful cleaning and the maintenance of hot water temperatures at a minimum of 60 degrees C to reduce the chances of Legionella multiplying. Further research into the ecology of Legionella in roof-collected rain water systems is indicated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An evaluation of measures for improving the quality of roof-collected rainwater

Rainwater itself is free from pathogens and contamination levels of stored rainwater are generally low if tanks are well protected with covers or lids but obvious sources of contamination of the rainwater runoff can originate from faecal matter deposited by birds, frogs, possums, rodents, and dead animals and insects, either on the roofs or in the gutters, or in the water tank itself. A number ...

متن کامل

A Rainwater Harvesting Technology by Roof Coating Using TiO2

Rainwater utilization has great potentials for recovering hydrological cycles, for buffering extreme run-off situations in the watercourses, and for reducing the costs for water supply in urban area. However, little information is available on the water qualities and runoff properties of collected rainwater, which is critical for efficient design and maintenance strategies of rainwater harvesti...

متن کامل

Identifying the major influences on the microbial composition of roof harvested rainwater and the implications for water quality.

Perceptions of the quality of roof harvested rainwater remain an impediment to widespread implementation of rainwater tanks on urban allotments. Previous literature reports on roof water quality have given little consideration to the relative significance of airborne environmental micro-organisms to roof catchment contamination and the issue of tank water quality. This paper outlines the findin...

متن کامل

Microbiological Values of Rainwater Harvested in Adelaide

In Australia, rainwater is an important source of water for many households. Unlike municipal water, rainwater is often consumed untreated. This study investigated the potential contamination of rainwater by microorganisms. Samples from 53 rainwater tanks across the Adelaide region were collected and tested using Colilert™ IDEXX Quanti-Tray*/2000. Twenty-eight out of the 53 tanks (53%) containe...

متن کامل

An outbreak of Legionnaires disease associated with a decorative water wall fountain in a hospital.

OBJECTIVE To detect an outbreak-related source of Legionella, control the outbreak, and prevent additional Legionella infections from occurring. DESIGN AND SETTING Epidemiologic investigation of an acute outbreak of hospital-associated Legionnaires disease among outpatients and visitors to a Wisconsin hospital. PATIENTS Patients with laboratory-confirmed Legionnaires disease who resided in ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Water research

دوره 42 6-7  شماره 

صفحات  -

تاریخ انتشار 2008