Operating room ventilation with laminar airflow shows no protective effect on the surgical site infection rate in orthopedic and abdominal surgery.

نویسندگان

  • Christian Brandt
  • Uwe Hott
  • Dorit Sohr
  • Franz Daschner
  • Petra Gastmeier
  • Henning Rüden
چکیده

OBJECTIVE To evaluate whether operating room (OR) ventilation with (vertical) laminar airflow impacts on surgical site infection (SSI) rates. DESIGN Retrospective cohort-study based on routine surveillance data. PATIENTS AND METHODS Sixty-three surgical departments participating voluntarily in the German national nosocomial infections surveillance system "KISS" were included (a total of 99,230 operations). Active SSI surveillance was performed according to the methods and definitions given by the US National Nosocomial Infection Surveillance system. Surgical departments were stratified according to type of OR ventilation used: (1) turbulent ventilation with high-efficiency particulate air-filtered air, and (2) HEPA-filtered (vertical) laminar airflow ventilation. Multivariate analyses were performed by the generalized estimating equations method to control for the following variables as possible confounders: (a) Patient-based: wound contamination class, ASA score, operation duration, patients' age and gender, endoscopic operation; (b) Hospital-based: the number of beds in the hospital, its academic status, operation frequency, and long-term participation in KISS. RESULTS The risk for severe SSI after hip prosthesis implantation was significantly higher using laminar airflow OR ventilation (1.63 < 1.06; 2.52>), as compared with turbulent ventilation. The adjusted odds ratios for the other operative procedures analyzed were: knee prosthesis 1.76 < 0.80, 3.85>; appendectomy 1.52 < 0.91, 2.53>; cholecystectomy 1.37 < 0.63, 2.97>; colon surgery 0.85 < 0.49, 1.49>; and herniorrhaphy 1.48 < 0.67; 3.25>. CONCLUSIONS Unexpectedly, in this analysis, which controlled for many patient and hospital-based confounders, OR ventilation with laminar airflow showed no benefit and was even associated with a significantly higher risk for severe SSI after hip prosthesis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Does a mobile laminar airflow screen reduce bacterial contamination in the operating room? A numerical study using computational fluid dynamics technique

BACKGROUND Air-borne bacteria in the operating room (OR) may contaminate the surgical wound, either by direct sedimentation from the air or indirectly, by contaminated sterile instruments. Reduced air contamination can be achieved with an efficient ventilation system. The current study assesses the additive effect of a mobile laminar airflow (MLAF) unit on the microbiological air quality in an ...

متن کامل

Transmission of Mycobacterium chimaera from Heater-Cooler Units during Cardiac Surgery despite an Ultraclean Air Ventilation System.

Heater-cooler units (HCUs) were recently identified as a source of Mycobacterium chimaera causing surgical site infections. We investigated transmission of this bacterium from HCUs to the surgical field by using a thermic anemometer and particle counter, videotape of an operating room equipped with an ultraclean laminar airflow ventilation system, and bacterial culture sedimentation plates in a...

متن کامل

Sterile Parts of Operating Gown during Lower Limb Joint Replacement Surgery

Background: The prevention of surgical site infection is one of the most concerning issues in operating rooms. Surgicalgowns are worn as one of the intraoperative strategies for infection prevention. The present study investigated whetherthe gowns remained sterile during the surgical procedure. Furthermore, this study examined which parts of the surgicalgown were more prone to...

متن کامل

Design and Manufacture of a Smart Orthopedic Pin Cutter for Use in the Operating Room and Patients Undergoing Orthopedic Surgery

Background and Aim: Since pin cutter is used in surgical operations involving screw and orthopedic plating and this is one of the most sensitive surgeries, saving time is very important along with reducing infection rate. The purpose of design the Mini-Pin Cutter is to replace a smaller, lighter, more efficient device than conventional and traditional cutters, which ultimately results in a comf...

متن کامل

Forced-air warming and ultra-clean ventilation do not mix: an investigation of theatre ventilation, patient warming and joint replacement infection in orthopaedics.

We investigated the capacity of patient warming devices to disrupt the ultra-clean airflow system. We compared the effects of two patient warming technologies, forced-air and conductive fabric, on operating theatre ventilation during simulated hip replacement and lumbar spinal procedures using a mannequin as a patient. Infection data were reviewed to determine whether joint infection rates were...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of surgery

دوره 248 5  شماره 

صفحات  -

تاریخ انتشار 2008