Soft robotic ventricular assist device with septal bracing for therapy of heart failure

نویسندگان

  • Isaac Wamala
  • Daniel Bautista-Salinas
  • Mossab Saeed
  • David Van Story
  • Thomas Thalhofer
  • Markus A. Horvath
  • Colette Abah
  • Pedro J. del Nido
  • Conor J. Walsh
  • Nikolay V. Vasilyev
چکیده

Previous soft robotic ventricular assist devices have generally targeted biventricular heart failure and have not engaged the interventricular septum that plays a critical role in blood ejection from the ventricle. We propose implantable soft robotic devices to augment cardiac function in isolated left or right heart failure by applying rhythmic loading to either ventricle. Our devices anchor to the interventricular septum and apply forces to the free wall of the ventricle to cause approximation of the septum and free wall in systole and assist with recoil in diastole. Physiological sensing of the native hemodynamics enables organ-in-the-loop control of these robotic implants for fully autonomous augmentation of heart function. The devices are implanted on the beating heart under echocardiography guidance. We demonstrate the concept on both the right and the left ventricles through in vivo studies in a porcine model. Different heart failure models were used to demonstrate device function across a spectrum of hemodynamic conditions associated with right and left heart failure. These acute in vivo studies demonstrate recovery of blood flow and pressure from the baseline heart failure conditions. Significant reductions in diastolic ventricle pressure were also observed, demonstrating improved filling of the ventricles during diastole, which enables sustainable cardiac output.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improvement of Left Ventricular Assist Device (LVAD) in Artificial Heart Using Particle Swarm Optimization

In this approach, the Left ventricular assist pump for patients with left ventricular failure isused. The failure of the left ventricle is the most common heart disease during these days. Inthis article, a State feedback controller method is used to optimize the efficiency of a samplingpump current. Particle Swarm Algorithm, which is a set of rules to update the position andvelocity, is applied...

متن کامل

Application of centrifugal pump in right ventricular failure due to pulmonary artery hypertension. (A case report)

Background: It has not been yet developed a ost suitable method to treat right ventricular failure due to pulmonar artery hypertention resulted from ventricular arrhythia. Though some case reports about patients ready to heart transplant using left assist device or biventral assist device as bridge have been published in Journals, but nocase concerning application of centrifugal pump for treatm...

متن کامل

Design an Equivalent Left Ventricular Assist Device for Medical Equipment Labs

LVAD is a mechanical pump supporting a weak heart function and blood flow. Sometimes, the heart may not recover fast enough to take over the pumping action immediately after surgery, in such patients a temporary support device has been employed to maintain the pumping action until the patient’s own heart recovers. This device can be considered as a temporary alternative before the process of ar...

متن کامل

Pop-up-inspired design of a septal anchor for a ventricular assist device

Heart failure (HF) is a serious condition in which the heart cannot pump sufficient blood to sustain the metabolic needs of the body. A common indication of failure is a low ejection fraction, or the volumetric proportion of blood ejected when the ventricle contracts. In end-stage HF, support from a ventricular assist device (VAD) can assume some or all of the heart’s pumping work, improving th...

متن کامل

Wearable Soft Robotic Device Supports the Failing Heart in vivo

Soft robots fabricated from low modulus, compliant materials hold significant potential for medical device applications that warrant safe, synergistic interaction with humans. We have recently applied this technology to develop ventricular assistive devices (VADs) that can externally massage the failing heart [1][2]. In heart failure (HF), the heart cannot provide sufficient pumping support to ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Science Robotics

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2017