Adequacy of a compartment model for CMRO2 quantitation using 15O-labeled oxygen and PET: a clearance measurement of 15O-radioactivity following intracarotid bolus injection of 15O-labeled oxyhemoglobin on Macaca fascicularis

نویسندگان

  • Hidehiro Iida
  • Satoshi Iguchi
  • Noboru Teramoto
  • Kazuhiro Koshino
  • Tsutomu Zeniya
  • Akihide Yamamoto
  • Nobuyuki Kudomi
  • Tetsuaki Moriguchi
  • Yuki Hori
  • Junichiro Enmi
  • Hidekazu Kawashima
  • Nadim Joni Shah
  • Jyoji Nakagawara
چکیده

We aimed at evaluating the adequacy of the commonly employed compartmental model for quantitation of cerebral metabolic rate of oxygen (CMRO2) using (15)O-labeled oxygen ((15)O2) and positron emission tomography (PET). Sequential PET imaging was carried out on monkeys following slow bolus injection of blood samples containing (15)O2-oxyhemoglobin ((15)O2-Hb), (15)O-labeled water (H2(15)O), and C(15)O-labeled hemoglobin (C(15)O-Hb) into the internal carotid artery (ICA). Clearance slopes were assessed in the middle cerebral artery territory of the injected hemisphere. The time-activity curves were bi-exponential for both (15)O2-Hb and H2(15)O. Single exponential fitting to the early (5 to 40 seconds) and late (80 to 240 seconds) periods after the peak was performed and the (15)O2-Hb and H2(15)O results were compared. It was found that a significant difference between the clearance rates of the (15)O2-Hb and H2(15)O injections is unlikely, which supports the mathematical model that is widely used to describe the kinetics of (15)O2-Hb and H2(15)O in cerebral tissues and is the basis of recent approaches to simultaneously assess CMRO2 and cerebral blood flow in a single PET session. However, it should be noted that more data are necessary to unequivocally confirm the result.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validity of using a 3-dimensional PET scanner during inhalation of 15O-labeled oxygen for quantitative assessment of regional metabolic rate of oxygen in man.

Use of 15O labeled oxygen (15O2) and positron emission tomography (PET) allows quantitative assessment of the regional metabolic rate of oxygen (CMRO2) in vivo, which is essential to understanding the pathological status of patients with cerebral vascular and neurological disorders. The method has, however, been challenging, when a 3D PET scanner is employed, largely attributed to the presence ...

متن کامل

Oxygen-15 labeled CO2, O2, and CO PET in small animals: evaluation using a 3D-mode microPET scanner and impact of reconstruction algorithms

BACKGROUND Positron emission tomography (PET) studies using 15O-labeled CO2, O2, and CO have been used in humans to evaluate cerebral blood flow (CBF), the cerebral oxygen extraction fraction (OEF), and the cerebral metabolic rate of oxygen (CMRO2) and cerebral blood volume (CBV), respectively. In preclinical studies, however, PET studies using 15O-labeled gases are not widely performed because...

متن کامل

Tumor blood flow measured by PET dynamic imaging of first-pass 18F-FDG uptake: a comparison with 15O-labeled water-measured blood flow.

UNLABELLED PET molecular imaging of 15O-labeled water is the gold standard for measuring blood flow in humans. However, this requires an on-site cyclotron to produce the short-lived 15O tracer, which is cost-prohibitive for most clinical PET centers. The purpose of this study was to determine if the early uptake of 18F-FDG could be used to measure regional blood flow in tumors in the absence of...

متن کامل

Validation of a simplified scatter correction method for 3D brain PET with 15O

OBJECTIVE Positron emission tomography (PET) enables quantitative measurements of various biological functions. Accuracy in data acquisition and processing schemes is a prerequisite for this. The correction of scatter is especially important when a 3D PET scanner is used. The aim of this study was to validate the use of a simplified calculation-based scatter correction method for 15O studies in...

متن کامل

A routine, automated synthesis of oxygen-15-labeled butanol for positron tomography.

The use of labeled butanol for autoradiographic and positron tomographic measurement of cerebral blood flow has been well established using radiocarbon labels. The advantages of the short half-life of oxygen-15 (15O) in doing sequential flow studies are also recognized. An automated procedure has been developed for the routine rapid and sequential synthesis of 15O-labeled butanol in amounts and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 34  شماره 

صفحات  -

تاریخ انتشار 2014