Duty cycle and modulation efficiency of two-channel Hadamard transform time-of-flight mass spectrometry.

نویسندگان

  • Oh Kyu Yoon
  • Ignacio A Zuleta
  • Joel R Kimmel
  • Matthew D Robbins
  • Richard N Zare
چکیده

Hadamard transform time-of-flight mass spectrometry (HT-TOFMS) is based on the pseudorandom gating of ion packets into a time-of-flight mass-to-charge analyzer. In its typical implementation, the technique is able to monitor continuous ion sources with a 50% duty cycle, independent of all other figures of merit. Recently, we have demonstrated that the duty cycle can be extended to 100% using patterned, two-channel detection. Two-channel HT-TOFMS involves the simultaneous optimization of paired one-channel experiments and imposes more stringent conditions to achieve high-quality spectra. An ion modulation device, known as Bradbury-Nielson Gate (BNG), is central to HT-TOFMS. It is an ideal deflection plate, capable of transmitting or deflecting an ion beam according to a known binary sequence without changing the times-of-flight of the ions. Analytical equations are derived that accurately describe the ion modulation process of the BNG as confirmed by good agreement with SimIon simulations and ion beam imaging experiments. From these expressions, the duty cycle and ion modulation efficiency were calculated for various BNG parameters, ion beam characteristics, and detector dimensions, which permit the optimum conditions to be chosen for the two-channel experiment. We conclude that the outer detector should be three times the maximum deflection angle to detect all deflected ions (100% duty cycle) and that the difference between the modulated ion counts in the sequence elements 0 and 1 should be maximized to achieve high modulation efficiency. This condition is best achieved by tight focusing of the ion beam in the center of the inner detector. When both channels are optimized, the two-channel advantage can be exploited to achieve a further improvement over a single-channel experiment.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hadamard transform time-of-flight mass spectrometry: more signal, more of the time.

Hadamard transform time-of-flight mass spectrometry (HT-TOF MS) is a type of mass analysis that was developed to couple continuous ion sources to the inherently pulsed nature of time-of-flight measurements. Unlike conventional TOF MS, the Hadamard transform method offers a duty cycle of 50%, with the possibility of extending it to 100%. Because it is a multiplexing technique, the attainable sig...

متن کامل

Hadamard transform time-of-flight mass spectrometry: a high-speed detector for capillary-format separations.

This work demonstrates that with an intrinsic duty cycle of 50% and spectral storage speeds up to 277 spectra s(-1) Hadamard transform time-of-flight mass spectrometry (HT-TOFMS) is a promising detector for any capillary-format separation that can be coupled to MS by electrospray ionization. Complete resolution of the components of a nine-peptide standard was achieved by coupling pressurized-ca...

متن کامل

Hadamard Transform Time-of-Flight Mass Spectrometry

A new mode of operation of a time-of-flight mass spectrometer (TOFMS) is described and demonstrated. A continuous ion beam emerging from the ion source is accelerated and then modulated by a pseudorandom sequence of “on” and “off” pulses. The data acquisition period is set to match the period of the modulation sequence, and data are acquired synchronously with the modulation of the ion beam. Th...

متن کامل

Toward artifact-free data in Hadamard transform-based double multiplexing of ion mobility-Orbitrap mass spectrometry.

The integration of ion mobility spectrometry (IMS) with a trap-based mass spectrometer (MS) such as Orbitrap using the dual gate approach suffers from low duty cycle. Efforts to improve the duty cycle involve the utilization of Hadamard transform-based double multiplexing which significantly improves the signal-to-noise ratio and duty cycle of the ion mobility-Orbitrap mass spectrometry (IM-Orb...

متن کامل

Effects of modulation defects on Hadamard transform time-of-flight mass spectrometry (HT-TOFMS).

In any Hadamard multiplexing technique, discrepancies between the intended and the applied encoding sequences may reduce the intensity of real spectral features and create discrete, artificial signals. In our implementation of Hadamard transform time-of-flight mass spectrometry (HT-TOFMS), the encoding sequence is applied to the ion beam by means of an interleaved comb of wires (Bradbury-Nielso...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of the American Society for Mass Spectrometry

دوره 16 11  شماره 

صفحات  -

تاریخ انتشار 2005