Polarized light based scheme to monitor column performance in a continuous foam fractionation column
نویسندگان
چکیده
BACKGROUND A polarized light scattering technique was used to monitor the performance of a continuously operated foam fractionation process. The S11 and S12 parameters, elements of the light scattering matrix, combined together (S11+S12) have been correlated with the bubble size and liquid content for the case of a freely draining foam. The performance of a foam fractionation column is known to have a strong dependence on the bubble size distribution and liquid hold up in foam. In this study the enrichment is used as a metric, representative of foam properties and column performance, and correlated to the S11+S12 parameter. RESULTS Three different superficial gas velocities (6.9, 7.5, and 10.6 cm/min) and four different pH values (4.8, 5.5, 6.5, and 7.5) are tested for the foam fractionation of a dilute solution of bovine serum albumin (0.1 mg/ml). As a result, at scattering angle of 125 degrees the magnitude of S11+S12 is higher as the pH increases. When the bubble sizes are small with a larger liquid content, the foam is strongly back scattering resulting in lower values of S11+S12 (at 125 degrees ) at pH = 4.8. The light scattering data and the enrichment values are measured over a period of 90 minutes and correlated using a linear model. The predictive power of the model was found to be statistically significant. CONCLUSION The time average S11+S12 shows a direct proportionality with the enrichment value, indicating that polarized light should be a valuable technique for monitoring foam fractionation columns. Additional knowledge of the nature of dependence between foam properties and S11+S12 combined with models relating the enrichment to the bubble size and liquid hold up is needed to develop an accurate diagnostics tool for monitoring enrichment utilizing S11+S12 measurements.
منابع مشابه
Theoretical analysis of the performance of a foam fractionation column.
A model system for theory and experiment which is relevant to foam fractionation consists of a column of foam moving through an inverted U-tube between two pools of surfactant solution. The foam drainage equation is used for a detailed theoretical analysis of this process. In a previous paper, we focused on the case where the lengths of the two legs are large. In this work, we examine the appro...
متن کاملPerformance of the Modified Precast Beam to Column Connection Placed on a Concrete Corbel
Precast concrete structures in Iran are generally designed as continuous columns with hinged beams, thereby making them simple frames. In this system in site show walls in two directions of buildings guaranteed lateral resisting system. However, in order to obtain a seismic resisting frame, the connection between beam and column should be moment resisting and ductile, allowing the formation of ...
متن کاملRow/Column-First: A Path-based Multicast Algorithm for 2D Mesh-based Network on Chips
In this paper, we propose a new path-based multicast algorithm that is called Row/Column-First algorithm. The proposed algorithm constructs a set of multicast paths to deliver a multicast message to all multicast destination nodes. The set of multicast paths are all of row-first or column-first subcategories to maximize the multicast performance. The selection of row-first or column-first appro...
متن کاملImmunoglobulin A Preparation from Human Pooled Plasma Using Plasma Fractionation and Ion Exchange Chromatography
Background: In this study we have prepared the IgA solution from normal human plasma using plasma fractionation and ion exchange chromatography. Materials and Methods: Using fractionation of plasma with cold ethanol (starting with 8% ethanol), fraction III was prepared as a suitable source for IgA preparation. Then it was treated with caprylic acid for separation of impurities. For enrichm...
متن کاملRemoving Copper from Contaminated Water Using Activated Carbon Sorbent by Continuous Flow
Introduction: A major concern of human being is accumulation and toxicity of heavy metals in their body. Copper is a heavy metal ion that in concentration of 2 mg/l can cause numerous complications. Different treatment methods have been proposed for removing metals from contaminated water by researchers. Among these methods, sorption seems a better method with high removal efficiency. In this s...
متن کامل