Positioning Training Tool for Radiography

نویسندگان

  • Toshinori Maruyama
  • Hideki Yamamoto
چکیده

Accurate positioning reduces the X-ray exposure of the subject and produces a valuable X-ray image for diagnosis. This paper describes the development of a positioning training tool that supports those studying to be radiological technologists in learning the positioning technique efficiently. Students perform the positioning on a personal computer using a three-dimensional computer graphics (3DCG) phantom constructed from computed tomography (CT) image data and confirm the produced plane image corresponding to the positioned phantom. It is expected that students will be able to undertake positioning training using our tool anywhere and at any time without using X-ray equipment. Repeated use of our training tool will help students attain a deep understanding of anatomy and acquire positioning skills efficiently and accurately.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Common Positioning Errors in Digital Panoramic Radiographies Taken In Mashhad Dental School

Introduction: The present study was aimed at evaluating common positioning errors on panoramic radiographs taken in the Radiology Department of Mashhad Dental School. Materials and methods: The study sample included 1,990 digital panoramic radiographs taken in the Radiology Department of Mashhad Dental School by a Planmeca Promax (Planmeca Oy, Helsinki, Finland), during a 2-year period (2010–20...

متن کامل

Film retakes in digital and conventional radiography.

OBJECTIVE To determine the film-retake rates and causes in digital radiography comparison to conventional X-rays method. STUDY DESIGN Comparative study. PLACE AND DURATION OF STUDY Radiology Department, Aga Khan University Hospital, Karachi, from January 2004 to December 2006. PATIENTS AND METHODS X-rays of different body parts, conducted during the year 2004, with conventional radiograph...

متن کامل

[Effectiveness of a positioning doll for radiography: through performance as a practice of radiography training and a questionnaire targeted for radiological technologists].

The effectiveness of a positioning doll for radiography training (XPD) and acquiring the techniques of radiography was evaluated through performing radiography practice for the students in our school of radiological technologists and a questionnaire for radiological technologists. We made a ranking test composed of a five-grade evaluation system of the 39 students for the techniques of radiogra...

متن کامل

Radiographic images repeats in Bandar Abbas teaching hospitals, Iran

Introduction: One of the obvious problems regarding radiography considered to be the malfunction of films and repeating the test, which leads to increase was carried out in hospital costs and irreparable radiation. The present research at shahid mohammadi teaching hospital of Bandar-Abbas, Iran. Methods: This decretive cross-sectional study was done within six months in shahid mohammadi and chi...

متن کامل

بررسی علل تکرار رادیوگرافی های پانورامیک دیجیتال در مراکز تصویربرداری دیجیتال دندانی

Abstract Background and purpose: Extensive application of x-ray as a diagnostic tool has created a global concern. Repeating a radiograph doubles radiation dose to the patient and staff. It was expected that development of digital facilities could decrease the rate of re-take of radiographs. The aim of this study was to investigate the causes for repeating digital panoramic radiographs. Mat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013