Determination of Polycyclic Aromatic Hydrocarbons in Groundwater Samples by Gas Chromatography-Mass Spectrometry After Pre-Concentration Using Cloud-Point Extraction with Surfactant Derivatization
نویسندگان
چکیده
A cloud-point extraction (CPE) method using the surfactant (30)p-tert-octylphenol polyoxyethylene (OPEO30) was proposed as the preceding step for the determination of polycyclic aromatic hydrocarbons (PAHs) by gas chromatography-mass spectrometry (GC-MS). Given the need for surfactant derivatization before the chromatographic analysis, the reaction conditions of coacervate derivatization were studied. The extraction process was also optimized, where surfactant concentration, temperature and time were analyzed as variables. The limits of detection obtained were between 0.02 and 0.05 μg L−1, and the recoveries of analytes were between 70 and 98%, with coefficient of variation better than 10.3%. The analytical method developed provides an efficient, precise and accurate method for the determination of the 16 priority PAHs, generating results in accordance with the USEPA 3510C method. The method was applied to the analysis of groundwater samples collected from artesian wells located at retail fuel stations.
منابع مشابه
Simultaneous Determination of 13 Priority Polycyclic Aromatic Hydrocarbons in Tehran’s Tap Water and Water for Injection Samples Using Dispersive Liquid-Liquid Micro Extraction Method and Gas Chromatography-Mass Spectrometry
Abstract Polycyclic aromatic hydrocarbons (PAHs) are classified as persistent and carcinogenic organic pollutants. PAHs contamination has been reported in water. Many of relevant regulatory bodies such as EU and EPA have regulated the limit levels for PAHs in drinking water. In this study, 13 priority polycyclic aromatic hydrocarbons (PAHs) were determined in tap water samples of Tehran and wat...
متن کاملSimultaneous Determination of 13 Priority Polycyclic Aromatic Hydrocarbons in Tehran’s Tap Water and Water for Injection Samples Using Dispersive Liquid-Liquid Micro Extraction Method and Gas Chromatography-Mass Spectrometry
Abstract Polycyclic aromatic hydrocarbons (PAHs) are classified as persistent and carcinogenic organic pollutants. PAHs contamination has been reported in water. Many of relevant regulatory bodies such as EU and EPA have regulated the limit levels for PAHs in drinking water. In this study, 13 priority polycyclic aromatic hydrocarbons (PAHs) were determined in tap water samples of Tehran and wat...
متن کاملSepration and determination trace amount of cadmium ions in real and water samples by cloud point extraction - flame atomic absorption spectrophotometry after preconcentration with non-ionic surfactant Triton-X114
2-(3- indolyl) – 4,5 di phynyl imidazole.(IDPI) was used as a complexing agent in cloud point extraction for the first time and applied for selective pre-concentration of trace amounts of cadmium. The method is based on the extraction of cadmium at pH= 7.0 by using non-ionic surfactant Triton-X114 and 2-(3- indolyl) – 4,5 di phynyl imidazole. (IDPI) as a chelating agent. The adopted concentrati...
متن کاملValidation of an Analytical Method for Determination of 13 priority polycyclic aromatic hydrocarbons in mineral water using dispersive liquid-liquid microextraction and GC-MS
Dispersive liquid liquid microextraction (DLLME) combined with gas chromatography–mass spectrometry (GC–MS) was used for the extraction and determination of 13 polycyclic aromatic hydrocarbons (PAHs) in mineral water samples. In this procedure, the suitable combination of extraction solvent (500 µL chloroform) and disperser solvent (1000 µL acetone) were quickly injected into the water sample (...
متن کاملValidation of an Analytical Method for Determination of 13 priority polycyclic aromatic hydrocarbons in mineral water using dispersive liquid-liquid microextraction and GC-MS
Dispersive liquid liquid microextraction (DLLME) combined with gas chromatography–mass spectrometry (GC–MS) was used for the extraction and determination of 13 polycyclic aromatic hydrocarbons (PAHs) in mineral water samples. In this procedure, the suitable combination of extraction solvent (500 µL chloroform) and disperser solvent (1000 µL acetone) were quickly injected into the water sample (...
متن کامل