Systemic effects of high dose inhaled steroids: comparison of beclomethasone dipropionate and budesonide in healthy subjects.

نویسندگان

  • P H Brown
  • S P Matusiewicz
  • C Shearing
  • L Tibi
  • A P Greening
  • G K Crompton
چکیده

BACKGROUND Systemic absorption of inhaled corticosteroids may adversely influence the function of the hypothalamo-pituitary-adrenal axis, bone metabolism, and circulating leucocytes. These changes can be used to assess the safety of different types and modes of administration of these drugs. METHODS The study was a randomised, double dummy, crossover design with nine healthy adults. It compared the effects of beclomethasone dipropionate and budesonide (given by metered dose aerosols with and without their respective large volume spacers (Volumatic and Nebuhaler) attached) on serum cortisol, 24 hour urinary free cortisol, and plasma osteocalcin concentrations, and circulating neutrophils and lymphocytes. Subjects inhaled the drug (1 mg) and matching placebo at 0900 and 2200 hours on each of six study days. Blood samples were taken hourly for six hours after the morning dose and at the end of the study period. RESULTS All results were within the reference ranges. Both drugs caused similar reductions in serum cortisol four to six hours after inhalation. These changes were not affected by the use of a large spacer and did not persist at 24 hours. Use of spacers tended to increase the haematological effects of the steroids. Beclomethasone dipropionate inhaled through a Volumatic provoked a rise in circulating neutrophils compared with placebo although lymphocyte numbers were unaffected. Budesonide did not influence neutrophil numbers but did reduce circulating lymphocytes, numbers of which were further reduced when the Nebuhaler was used. There were no significant changes in plasma osteocalcin concentration or 24 hour urinary free cortisol excretion with budesonide, with or without a spacer. Beclomethasone dipropionate inhaled without a spacer reduced urinary cortisol and plasma osteocalcin at 24 hours; however, use of the Volumatic protected against these effects. CONCLUSIONS Attaching a Volumatic reduces the systemic effects of 2 mg aerosol beclomethasone dipropionate on the hypothalamo-pituitary-adrenal axis and circulating osteocalcin concentrations. This study did not establish whether the Nebuhaler reduces the systemic effects of budesonide. When large spacers are used, 2 mg per day of beclomethasone dipropionate and budesonide seem to be equivalent in terms of unwanted effects.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Adrenal function and high dose inhaled corticosteroids for asthma.

OBJECTIVE To investigate effects on adrenal function of fluticasone, a recently released inhaled steroid preparation with lower systemic bioavailability than beclomethasone dipropionate. METHODS 34 children on high doses (400-909 micrograms/m2/d) of inhaled beclomethasone dipropionate or budesonide were recruited into a double blind, crossover study investigating the effects on adrenal functi...

متن کامل

Bone turnover during high dose inhaled corticosteroid treatment.

This study was performed to determine the effects of high doses of two inhaled corticosteroids, beclomethasone dipropionate and budesonide, on biochemical indices of bone turnover (urinary hydroxyproline:creatine and calcium:creatinine ratios, plasma alkaline phosphatase, and parathyroid hormone). Twelve healthy male doctors, aged 25-36 (mean 30) years, were studied. After a week's run in perio...

متن کامل

Effect of a volumatic spacer and mouth rinsing on systemic absorption of inhaled corticosteroids from a metered dose inhaler and dry powder inhaler.

BACKGROUND High doses of inhaled corticosteroids are absorbed systemically and may cause long term side effects. As rinsing the mouth out after use and inhaling through a spacing device may reduce systemic absorption this has been further investigated. METHODS Three crossover studies were carried out to assess the effect of budesonide given by dry powder inhaler (Turbuhaler) with and without ...

متن کامل

Bone mineral density in asthmatic patients treated with inhaled corticosteroids: a case-control study.

Recent studies suggest that inhaled corticosteroids can adversely affect bone metabolism. The objective of this study was to evaluate the importance of these adverse effects in a case-control study. Bone mineral density (BMD) was measured in 48 asthmatic adults (15 males and 33 females) treated with inhaled steroids (beclomethasone or budesonide) and in 48 gender and age-matched healthy subject...

متن کامل

Effect of eight months of inhaled beclomethasone dipropionate and budesonide on carbohydrate metabolism in adults with asthma.

BACKGROUND The safety of high dose inhaled steroids has been a subject of debate. The efficacy and safety of beclomethasone dipropionate and budesonide inhalations were evaluated by measuring their effects on pulmonary function, on the hypothalamic-pituitary-adrenocortical axis, and on carbohydrate metabolism in adults with unstable asthma. METHODS Fifteen adults with unstable asthma and 15 h...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Thorax

دوره 48 10  شماره 

صفحات  -

تاریخ انتشار 1993