Pulse oximetry in preterm infants.
نویسندگان
چکیده
One hundred and twenty five measurements of arterial oxygen saturation (Stcao2) obtained with a transcutaneous pulse oximeter were compared with direct arterial oxygen tension (Pao2) in 13 preterm infants with predominantly fetal haemoglobin. Stcao2 of 86-92% corresponded to Pao2 of 5-13 kPa. Stcao2 above 92%, however, was sometimes associated with Pao2 above 13 kPa.
منابع مشابه
Resuscitation of very preterm infants with 30% vs. 65% oxygen at birth: study protocol for a randomized controlled trial
BACKGROUND Resuscitation at birth with 100% oxygen is known to increase the oxidative burden with concomitant deleterious effects. Although fractions of inspired oxygen (FiO₂) < 100% are widely used in preterm infants, starting resuscitation at a (too) low FiO₂ may result in hypoxia. The objective of this study is to compare the safety and efficacy of resuscitating very preterm infants with an ...
متن کاملComparison of noninvasive techniques to measure blood pressure in newborns.
OBJECTIVE To compare blood pressure measurements in newborn infants using the flush method, pulse oximetry and oscillometry according to Doppler findings. METHODS Noninvasive blood pressure measurements were made using three techniques (flush method, pulse oximetry and oscillometry) in three groups of newborns: 15 normal term infants, 16 stable preterm infants, and 14 critically ill infants. ...
متن کاملEvaluation of Pulse Oximetry in the Early Detection of Congenital Heart Diseases in Newborns
Background: Congenital heart diseases, which are asymptomatic at birth, are the most important causes of infant mortality. This study aimed to evaluate the role of pulse oximetry in the early detection of congenital heart diseases among newborns.Methods: In this cross-sectional descriptive study, 1230 newborns who were born in university hospitals in an urban area of Iran were placed unde...
متن کاملPrevention of retinopathy of prematurity in preterm infants through changes in clinical practice and SpO2 technology
AIM To identify whether pulse oximetry technology is associated with decreased retinopathy of prematurity (ROP) and laser treatment. METHODS Inborn infants <1250 g who had eye exams were compared at two centres in three periods. In Period 1, SpO₂ target was ≥93% and pulse oximetry technology was the same in both Centres. In Period 2, guidelines for SpO₂ 88-93% were implemented at both centres...
متن کاملAccuracy of pulse oximetry in assessing heart rate of infants in the neonatal intensive care unit.
AIM To determine the accuracy of pulse oximetry measurement of heart rate in the neonatal intensive care unit. METHODS Stable preterm infants were monitored with a pulse oximeter and an ECG. The displays of both monitors were captured on video. Heart rate data from both monitors, including measures of signal quality, were extracted and analysed using Bland Altman plots. RESULTS In 30 infant...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Archives of disease in childhood
دوره 62 9 شماره
صفحات -
تاریخ انتشار 1987