Skin and chest wall dose with multi-catheter and MammoSite breast brachytherapy: Implications for late toxicity.
نویسندگان
چکیده
PURPOSE Accelerated partial breast irradiation (APBI) continues to increase in popularity. Up to 14% of patients treated with the MammoSite (MS) report some degree of chronic pain, which may be related to chest wall toxicity. Reports from several institutions using the multicatheter (MC) technique have not shown associated elevated chest wall toxicity. Additionally, a recent investigation has suggested that increased toxicity may occur with the MS when the dose to the chest wall exceeds 125% of the prescribed dose. This investigation compares the skin and chest wall doses of a cohort of patients treated with the MC technique to a group treated with the MS. METHODS AND MATERIALS The dosimetric data for 43 patients treated with the MC technique and 83 patients treated with the MS at Virginia Commonwealth University were reviewed. This cohort represents consecutively treated patients from our most recent experience to minimize any learning curve effect on dosimetry. Plans were generated using 3D software (Brachyvision, Varian Medical Systems, Inc., Palo Alto, CA). Multiple dwell positions were used for all MS patients to optimize dose delivery. The minimum distances from the planning target volume to the skin and chest wall were calculated, as well as the maximum doses delivered to the skin and chest wall. RESULTS The mean skin distances for patients treated with the MC technique and the MS were 0.5 and 0.9cm, respectively (p<0.002). Despite the significantly smaller mean skin distance, the mean skin dose for the MC technique was only 2.3Gy per fraction (67% of prescription dose). The mean skin dose for the MS was 3.2Gy per fraction (94% of prescription dose, p<0.001). The mean chest wall distance was 0.9cm for the MC technique and 1.0cm for the MS (p=0.55). Again, the mean chest wall dose for the MC technique was only 2.3Gy per fraction (67% of prescription dose). The mean skin dose for the MS was 3.6Gy per fraction (105% of prescription dose, p<0.001). The percentage of patients receiving skin doses in excess of 125% for the MC and MS were 0% and 9.6%, respectively. The percentage of patients receiving chest wall doses in excess of 125% for the MC and MS were 0% and 38.6%, respectively. CONCLUSION The MC technique results in more conformal dose delivery, with significantly lower mean skin and chest wall doses. Treatment with the MS was associated with significantly more patients receiving doses to the skin or chest wall in excess of 125% of the prescription. Given the limited followup available for the MS, and the significant dose delivered to the chest wall, the use of this device may be associated with a higher incidence of late chest wall toxicity than previously expected.
منابع مشابه
A Comparison of Skin Dose Delivered with MammoSite and Multicatheter Breast Brachytherapy
Background: Accelerated partial breast irradiation via interstitial balloon brachytherapy is a fast and effective treatment method for certain early stage breast cancers however skin, chest wall and Lung doses are correlated with toxicity in patients treated with breast brachytherapy.Objective: To investigate the percentage of the dose received by critical organ (skin), thermoluminescence detec...
متن کاملProof of Symmetric Dose Distribution in Mammosite Applicator in Breast Brachytherapy with MCNP Simulation
Introduction: In brachytherapy treatments, high-dose sources are used in interstitial placement. In this paper, the modeling of a common breast cancer treatment applicator called MammoSite is done by the Monte Carlo simulation code. Then, to study and calculate the amount of doses in the breast and the dose rate of the organs at risk of radiation, including: lungs, ribs and ski...
متن کاملA Comparison of Skin Dose Delivered with MammoSite and Multicatheter Breast Brachytherapy
BACKGROUND Accelerated partial breast irradiation via interstitial balloon brachytherapy is a fast and effective treatment method for certain early stage breast cancers however skin, chest wall and Lung doses are correlated with toxicity in patients treated with breast brachytherapy. OBJECTIVE To investigate the percentage of the dose received by critical organ (skin), thermoluminescence dete...
متن کاملCalculation of absorbed dose rate in the lungs, ribs and skin by the mammosite applicator in breast cancer brachytherapy with MCNP
Introduction: Breast cancer is the most common cancer among women. Brachytherapy is one of the ways to treat breast cancer. In brachytherapy treatments, high-dose sources are used in interstitial placement. Here, Iridium-192 is used. This source emits gamma rays with energies ranging from 136 kV to 1060 kV electron volts. The activity of the used spring is 10 Ci. The simulated ...
متن کاملAcute toxicity and early cosmetic outcome in patients treated with multilumen balloon brachytherapy with skin spacing ≤ 7.0 millimeters
PURPOSE To review institutional experience treating patients who underwent breast conserving surgery and adjuvant accelerated partial breast irradiation with multilumen balloon brachytherapy (MLB) with close skin spacing (≤7 mm). MATERIAL AND METHODS Since July 2009, 26 patients with skin spacing ≤ 7.0 mm were treated with breast-conserving therapy and adjuvant MLB brachytherapy. Patients wer...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Brachytherapy
دوره 8 2 شماره
صفحات -
تاریخ انتشار 2009