High Pressure Spark Gap Recovery after Overvolted Breakdown

نویسنده

  • Stuart Moran
چکیده

A spark gap at pressures from 100 kPa to 7 MPa with various gases is fired by overvolting the electodes. The recovery of the gap is studied using a second identical pulse to test the voltage holdoff during the recovery period. A TV camera, interferometer and a spinning mirror camera are also used to record arc locations and density profiles. The gas is stationary during the recovery. Breakdown voltages go up to 130 kV, currents are hundreds of amps and voltage risetimes are about 1 kV/ nsec. Results show the effects of gas species, electrode material and pressure on both breakdown voltages and recovery curves. The recovery of the ability to be overvolted occurs much slower than the recovery to DC breakdown voltages. The effects of the first arc on the second arc locations are shown as well as density profiles using a Mach-Zender interferometer.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Study of Breakdown Voltages for Triggered Spark Gap Switches

This study explains the breakdown mechanism in different triggered spark gap switches. Two different trigger electrode configurations are tested for the switch predischarge operation in a nitrogen laser circuit. The behavior of the breakdown voltage, when a trigger pulse is applied to the trigger electrode, is investigated, and the results are reported. Based on the experimental measurements ne...

متن کامل

Numerical and experimental investigation of dielectric recovery in supercritical N2

A supercritical (SC) nitrogen (N2) switch is designed and tested. The dielectric strength and recovery rate of the SC switch are investigated by experiments. In order to theoretically study the discharge and recovery process of the SC N2 switch under high repetition rate operation, a numerical model is developed. For SC N2 with initial parameters of p = 80.9 bar and T = 300 K, the simulation re...

متن کامل

Effect of electrode erosion on the required ignition voltage of spark plug in CNG spark ignition engine

In this article, the electrode erosion and the gap growth of spark plugs were measured on of a CNG fueled engine after durability tests. Then, the required ignition voltage and the spark quality were investigated by a spark plug test rig. Considering results of measurements, the gap growth increased as the running time increased. Thus, the gap growth of spark plugs with 200 and 280 hours runnin...

متن کامل

Statistical Characteristics of the Output Voltage in Compact Marx Generators

Compact Marx generators are widely used as portable pulse generator in different industrial applications, where high power pulses with rise times of order of some tens of nanoseconds are needed. For those applications, closing switches with very short delay and jitter times have to be used. Considering the fact that the breakdown of spark gap is a statistical process, the delay times of the clo...

متن کامل

A simple high-voltage high current spark gap with subnanosecond jitter triggered by femtosecond laser filamentation

We describe a simple, sturdy and reliable spark gap operating with air at atmospheric pressure and able to switch currents in excess of 10 kA with sub-nanosecond jitter. The spark gap is remotely triggered by a femtosecond laser filament. Many applications rely on the initiation of a well controlled discharge between two charged electrodes. For high current applications, a gas-filled trigger is...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015