Prospective self-gating for simultaneous compensation of cardiac and respiratory motion.

نویسندگان

  • Martin Buehrer
  • Jelena Curcic
  • Peter Boesiger
  • Sebastian Kozerke
چکیده

Segmented cardiac acquisitions generally require the use of an electrocardiogram (ECG) in combination with a breathhold or a respiratory navigator placed on the diaphragm. These techniques necessitate patient cooperation and increase the complexity of cardiac imaging. The ECG signal may be distorted inside the magnet by interferences from radiofrequency and gradient action. Breathhold acquisition limits the total scan time, while navigators on the diaphragm might not fully reflect respiratory-induced motion of the heart. To overcome some of these problems, several self-gating (SG) or "wireless" techniques have recently been presented. All of these approaches, however, are based on either cardiac triggering or respiratory gating, or the data are processed retrospectively, reducing the efficiency of data acquisition. In this work a prospective SG approach for free-breathing imaging is presented that requires neither ECG gating nor respiratory navigation. The motion data used for cardiac triggering and respiratory gating are extracted from the repeatedly acquired k-space center. Based on computer simulations and in vivo data of the heart, it is shown that cardiac as well as respiratory motion can be accurately extracted in real time. Using the method proposed, the scan efficiency could be significantly increased while preserving image quality relative to retrospective SG approaches.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Three-dimensional Whole-Heart Cine MRI using Prospective Self-Gating for Compensation of Cardiac and Respiratory Motion

Introduction: Two-dimensional (2D) breath-hold and ECG-triggered cine MRI is frequently used to assess cardiac function. However this technique requires cooperation from the patient, and the MR acquisition has to be synchronized with the cardiac cycle using ECG. To control respiratory motion, the subject has to perform breath-holds or the position of the diaphragm has to be tracked using a resp...

متن کامل

Advanced Motion Correction Methods in PET

With the arrival of increasingly higher resolution PET systems, small amounts of motion can cause significant blurring in the images, compared to the intrinsic resolutions of the scanners. In this work, we have reviewed advanced correction methods for the three cases of (i) unwanted patient motion, as well as motions due to (ii) cardiac and (iii) respiratory cycles. For the first type of ...

متن کامل

The Bioimpedance Technique in Respiratory - and Dual - Gated Positron Emission Tomography Imaging

Respiratory and cardiac motion artefacts degrade image quality in positron emission tomography (PET) imaging and may significantly affect the qualitative and quantitative evaluation of images. At worst, misguided interpretation may lead to wrong diagnosis and inadequate or unnecessary treatment. The aim of this thesis was to study the feasibility of the bioimpedancebased measurement technique f...

متن کامل

3D SPACE Arterial Wall Imaging with Prospective Self-Gating for Motion Compensation

reformatted images from non-gated and self-gated SPACE imaging. Note that images suffered from severe motion artifacts due to swallowing without self-gating motion compensation. Figure 2. (a) Correlation coefficients calculated between each projection and the reference profile; (b) Self-gating projection signals of the neck as a function of time; (c) Two projection signals acquired with and wit...

متن کامل

Improved respiratory motion self-gating in cardiovascular MRI

Background Respiratory motion compensation is often required in cardiovascular MRI applications especially when the scan time is not suitable for breath-hold. Respiratory self-gating (RSG) is a technique that estimate the respiratory motion based on k-space signal from the imaging object and is especially advantageous in CINE-like applications where conventional diaphragm navigator frequently i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 60 3  شماره 

صفحات  -

تاریخ انتشار 2008