Investigating the impacts of ageing and moisture on dielectric response of oil/paper insulation systems

نویسنده

  • T. K. Saha
چکیده

The oil/paper insulation system in a transformer degrades under various chemical, thermal and electromechanical stresses during its operation. Dielectric response measurements like the Return Voltage Measurement (RVM) and Polarisation and Depolarisation Current (PDC) measurement are currently being used for condition assessment of the insulation. In the current research project, the ageing condition and the moisture content of both paper and oil samples have been varied over a controlled range and their effects on the dielectric response measurements have been investigated. Experimental results are provided in this paper to demonstrate the effects of both ageing and moisture content of paper and oil on the RVM and PDC results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Estimation of Moisture in Transformer Insulation Using Dielectric Frequency Response Analysis by Heuristic Algorithms

Transformers are one of the most valuable assets of power systems. Maintenance and condition assessment of transformers has become one of the concerns of researchers due to huge number of transformers has been approached to the end of their lifetimes. Transformer’s lifetime depends on the life of its insulation and the insulation’s life is strongly influenced by its moisture attraction as well....

متن کامل

Separation of Ageing and Moisture Impacts on Transformer Insulation Degradation by Polarisation

This paper describes an accelerated ageing experiment of transformer oil/paper insulation with preset moisture levels. These samples were tested with return voltage and polarisation/depolarisation measurements. Molecular weight has also been measured with Gel Permeation Chromatography (GPC). Results suggested the impact of moisture on the ageing of oil/paper insulation. An attempt has been made...

متن کامل

ICSD 2007 – International Conference on Solid Dielectrics ( 9 th IEEE

The measurement of oil-paper insulation systems in the frequency domain provides novel diagnostic methods for quality control of materials and highvoltage power transformers. The first task is to measure and to analyse the dielectric behaviour of oil-paper insulation systems and their dependency on material quality, moisture content and ageing products in oil, paper and pressboard. Furthermore,...

متن کامل

A Feasible Solution to Distinguish the Transformer Winding Deformation from Insulation Characteristic Impacts on FRA Spectrum

Frequency Response Analysis (FRA) is popular technique which has been used since the last decade as a diagnostic method for transformers. However, accurate interpretation of FRA measurements is still challenging. Recent studies reveal that apart from winding deformation, FRA data can also be influenced by moisture variation in transformer paper insulation. Hence, a specific transformer’s model ...

متن کامل

Investigating the Transformer Operating Conditions for Evaluating the Dielectric Response

This paper presents an experimental investigation of transformer dielectric response and solid insulation water content. The dielectric response was carried out on the base of Hybrid Frequency Dielectric Spectroscopy and Polarization Current measurements method (FDS &PC). The calculation of the water content in paper is based on the water content in oil and the obtained equilibrium curves. A re...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003