The Quadripolar Left Ventricular Lead: An Effective Alternative for Phrenic Nerve Stimulation
نویسنده
چکیده
Despite the number of papers that suggest the benefit of optimization of location of left ventricular leads, every implanter knows the difficulty in going to an alternate lead position and location. Similarly, often, microdisplacement of the left ventricular (LV) lead post implant, can change grand success into abject failure forcing the electrophysiologist to sometimes actually turn off left ventricular pacing. Phrenic nerve stimulation (PNS) along the only posterolateral vein is not an uncommon situation where one has to back out from a procedure.
منابع مشابه
Quadripolar Left Ventricular Lead in a Patient with CRT-D Does Not Overcome Phrenic Nerve Stimulation
Effective cardiac resynchronization therapy (CRT) requires an accurate atrio-biventricular pacing system. The innovative Quartet lead is a quadripolar, over-the-wire left ventricular lead with four electrodes and has recently been designed to provide more options and greater control in pacing vector selection. A lead with multiple pacing electrodes is a potential alternative to physical adjustm...
متن کاملQuadripolar Leads in Cardiac€Resynchronization Therapy
Ma Despite the benefit of cardiac resynchronization therapy (CRT) in patients with heart failure and conduction delay, a considerable number of patients do not respond substantially. Left ventricular lead position is an important factor in response, restricted by the patient’s specific anatomy and local pathophysiology. Quadripolar leads could enhance response to CRT, offering 4 pacing location...
متن کاملCardiac Resynchronization Therapy Delivered Via a Multipolar Left Ventricular Lead is Associated with Reduced Mortality and Elimination of Phrenic Nerve Stimulation: Long‐Term Follow‐Up from a Multicenter Registry
INTRODUCTION Cardiac resynchronization therapy (CRT) using quadripolar left ventricular (LV) leads provides more pacing vectors compared to bipolar leads. This may avoid phrenic nerve stimulation (PNS) and allow optimal lead placement to maximize biventricular pacing. However, a long-term improvement in patient outcome has yet to be demonstrated. METHODS A total of 721 consecutive patients wi...
متن کاملDiaphragmatic stimulation caused by cardiac resynchronization treatment.
A 69-year-old man with a history of severe nonischemic cardiomyopathy managed with a cardiac resynchronization-defibrillator presented to the outpatient clinic with uncomfortable pulsation over the left upper-abdominal area when lying on his left side. He was hemodynamically stable. When he was recumbent in a left-lateral position, there were visible and palpable contractions of the left upper-...
متن کاملA Meta-Analysis Of Quadripolar Versus Bipolar Left Ventricular Leads On Post-Procedural Outcomes.
Objective: We aimed to perform a meta-analysis from eligible studies to analyze the true impact of QL when compared with BL with regard to post-procedural outcomes including lead deactivation, revision or replacement. Background: Many observational and retrospective studies showed that quadripolar left ventricular leads (QL) are associated with better outcomes and fewer complications when compa...