Design, Installation, and Field Verification of Integrated Active Desiccant Hybrid Rooftop Systems Combined with a Natural Gas Driven Cogeneration Package

نویسنده

  • John Fischer
چکیده

This report summarizes a research/demonstration project in which a new high school facility was designed and constructed to combine a custom built 230 kW cogeneration package with four integrated active desiccant rooftop (IADR) systems to serve as high-efficiency dedicated outdoor air systems (DOAS). The IADR systems were modified to include hot water coils to use the waste heat provided by the engine jacket water for desiccant regeneration during the peak cooling season and heating during peak heating conditions. Each IADR was coupled with a total energy recovery module for outdoor air preconditioning. These four DOAS serve variable air volume (VAV) air handling units, designed to handle the space sensible load requirements. The outdoor air dew point delivered by the DOAS is controlled based on the space humidity conditions in order to accommodate all of the outdoor and internal latent loads. At the direction of the owner, all systems at this site are packaged, vapor-compression heat pumps. This also includes the main VAV air handlers which are served by remote-mounted (split system), custom designed packaged heat pump condensing units. Extensive instrumentation was provided for all HVAC systems. Actual data is provided to show state points throughout the advanced HVAC system to summarize design performance at four separate outdoor conditions. The performance of the advanced system is compared to a conventional HVAC system to show the potential savings in energy consumption and peak demand. The advanced " integrated energy systems " approach detailed in this report provides an effective roadmap for constructing and operating comfortable, healthy, energy efficient schools (and other facilities) that follow current ASHRAE recommendations and meet all code requirements. This report also discusses the challenges and important design decisions that need to be made when selecting and installing a cogeneration system to serve active desiccant DOAS. The primary objective of this research project was to demonstrate the performance advantages of advanced " integrated energy systems " and " encourage further widespread adoption and implementation " of such systems. A further objective was to incorporate an advanced, integrated energy system into a conventional high school facility, where the level of design sophistication is typically limited and where budgetary concerns are high. This report summarizes a three-year project where a new high school facility was designed and constructed to combine a prepackaged cogeneration " prime mover " with prepackaged integrated active desiccant rooftop (IADR) systems to serve as dedicated outdoor air …

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Thermodynamic analysis of three combined power and refrigeration ‎Systems based on a demand

Three combined power and refrigeration system are introduced to compare and analyze for a defined demand and same fuel consumption based on thermodynamic parameters in a 24 hours period. Gas turbine and/or steam turbine are used for power generation and also ejector refrigeration cycle is used to produce cooling. These three systems are named as GER, SER and GSER. The results of three systems a...

متن کامل

A Combined Expert System/case-based Reasoning Approach for Cogeneration Plant Design

The paper deals with the design problem of natural gas cogeneration systems. Despite its complexity, this design problem subjected to several constraints is properly solved by humans, which suggests the use of artificial intelligence (AI). Moreover, the design process is strongly based on knowledge that experts have in a domain, so that the AI techniques known as knowledge-based systems (KBS) a...

متن کامل

Field Test and Performance Verification: Integrated Active Desiccant Rooftop Hybrid System Installed in a School Final Report: Phase 4a

Reports produced before January 1, 1996, may be purchased by members of the public from the following source: This report was prepared as an account of work sponsored by an agency of the United States government. Neither the United States government nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for th...

متن کامل

Thermodynamic Analysis of New Cogeneration Cycle Based on Gaynarje Hotspring

Gaynarje spring is one of the hottest springs in the world and is located around Meshginshahr in northwestern Iran. Because of the water with a temperature of 82 ºC, it is not appropriate to use this mineral water for swimming and bathing. In this study, in addition to lowering the water temperature to the appropriate swimming temperature (29 ºC), the hot water is used for power and natural gas...

متن کامل

Superstructure of Cogeneration of Power, Heating, Cooling and Liquid Fuels Using Gasification of Feedstock with Primary Material of Coal for Employing in LNG Process

Using absorption refrigeration cycles instead of vapor compression refrigeration cycles can drastically decrease energy consumption. In these systems, high level of energy consumption is reduced due to the partially elimination of vapor compression refrigeration systems. On the other hand, utilization of waste heat of the plant, which is a very good opportunity for energy saving,  is possible. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008