Speciation of chromium in cow’s milk by solid-phase extraction/dynamic reaction cell inductively coupled plasma mass spectrometry (DRC-ICP-MS)†
نویسندگان
چکیده
Chromium can act either as an essential micronutrient or a chemical carcinogen, depending on its oxidation state. Of the two most stable chromium oxidation states, Cr(VI) is a known carcinogen, while Cr(III) is an essential element. Determination of total Cr cannot therefore be used to evaluate food safety of dairy products, as speciation is required for accurate assessment of potential toxicity. In this study, total Cr was determined by DRC-ICP-MS after mineralisation of freeze-dried milk samples. Chromabond NH2 ion-exchange columns were used to separate Cr(VI) from Cr(III). During the separation process, Cr(VI) was selectively adsorbed onto the Chromabond NH2 column. The retained Cr(VI) was subsequently eluted with two column volumes of 2 M HNO3 and diluted to a final volume of 10 mL. After separation, the Cr(VI) was quantified by DRC-ICP-MS, using O2 as the reactive gas, to alleviate polyatomic ion interference. An O2 gas flow rate of 0.85 ml/min and a high-pass rejection parameter q (Rpq) 1⁄4 0.5, provided the best compromise signal-to-noise ratio. The method was validated through determining the recovery in milk samples spiked with Cr(VI). The recoveries were quantitative and ranged from 96.4 to 99.2%. A whole milk powder reference material (NIST SRM 8435) was used to evaluate the accuracy of the total Cr quantification method. The observed value showed concordance with the certified value. The limits of detection (LOD) were 0.091 and 0.085 mg/L for total Cr and Cr(VI), respectively. These findings are important for the determination of maximum residue levels (MRLs) of Cr(VI) in dairy products.
منابع مشابه
Elan Drc Icp-ms System with Dynamic Bandpass Tuning
Introduction Inductively Coupled Plasma Mass Spectrometry (ICP-MS) typically provides detection limits in the low-ppt to sub-ppt range for all but a few of over 70 elements. Unfortunately, for a handful of elements, conventional ICP-MS cannot provide the best possible detection limits. The detection limits for these elements are limited by plasma or sample matrix-based polyatomic interferences....
متن کاملApplication of a dynamic reaction cell (DRC) ICP-MS in chromium and iron determinations in rock, soil and terrestrial water samples.
Despite environmental and geochemical interests, Cr and Fe have been left beyond the reach of determinations by ICP-MS due to severe interferences originating from Ar. The applicability of a dynamic reaction cell (DRC)-ICP-MS has been examined for determinations in environmental and geochemical samples. The reaction with NH(3) in the DRC system provides an eligible technique to determine Cr, be...
متن کاملDetermination of iodine and bromine compounds by ion chromatography/dynamic reaction cell inductively coupled plasma mass spectrometry.
An inductively coupled plasma mass spectrometer (ICP-MS) was used as an ion chromatographic detector for the speciation of iodine and bromine. Gradient elution using NH4NO3 at pH 10 allowed the chromatographic separation of ionic iodine (I- and IO3-) and bromine (Br- and BrO3-) species in less than 8 min. Effluents from the ion-exchange column were delivered to the nebulization system of ICP-MS...
متن کاملDetermination of sub-ppb cadmium in urine by solid-phase extraction and inductively coupled plasma-mass spectrometry.
In order to determine low levels of Cd in urine samples, we tried to remove Mo interference using ICP-MS with a dynamic reaction-cell technique, but failed due to the low sensitivity and the variance with the standards. We then performed solid-phase extraction (SPE) before the ICP-MS measurement. A commercially available chelating resin, NOBIAS PA-1, was used for SPE, and could effectively remo...
متن کاملDetermination of Trace Elements in High-Purity Molybdenum by Solid-Phase Extraction/ICP-MS
We attempted a simple pretreating method consisting of solid-phase extraction using bonded silica gel with benzenesulfonic acid (SCX) as the solid-phase sorbent to determine trace elements in pure molybdenum samples by means of inductively coupled plasma mass spectrometry (ICP-MS). Molybdenum was anionized by adding hydrogen peroxide solution to a sample decomposed with acid, and separated from...
متن کامل