Schlieren laser Doppler flowmeter for the human optical nerve head with the flicker stimuli.
نویسندگان
چکیده
We describe a device to measure blood perfusion for the human optic nerve head (ONH) based on laser Doppler flowmetry (LDF) with a flicker stimuli of the fovea region. This device is self-aligned for LDF measurements and includes near-infrared pupil observation, green illumination, and observation of the ONH. The optical system of the flowmeter is based on a Schlieren arrangement which collects only photons that encounter multiple scattering and are back-scattered out of the illumination point. LDF measurements are based on heterodyne detection of Doppler shifted back-scattered light. We also describe an automated analysis of the LDF signals which rejects artifacts and false signals such as blinks. By using a Doppler simulator consisting of a lens and a rotating diffusing wheel, we demonstrate that velocity and flow vary linearly with the speed of the wheel. A cohort of 12 healthy subjects demonstrated that flicker stimulation induces an increase of 17.8% of blood flow in the ONH.
منابع مشابه
Influence of diffuse luminance flicker on choroidal and optic nerve head blood flow.
PURPOSE In the retina there is general agreement that blood flow adapts in response to different conditions of light and darkness including diffuse luminance flicker. By contrast, regulation of choroidal blood flow in response to different light conditions is still a matter of controversy. Thus, we investigated the effect of diffuse luminance flicker on choroidal and optic nerve head blood flow...
متن کاملTwo dimensional mapping of the perfusion of the retina and optic nerve head.
AIM To present a new non-invasive method of performing a high definition topography of perfused vessels of the retina and the optic nerve head with simultaneous evaluation of blood flow. METHOD By a combination of a laser Doppler flowmeter with a scanning laser system the perfusion of the retina and the optic nerve head is visualised. The principles of measuring blood flow by laser Doppler fl...
متن کاملShort-term increase of intraocular pressure does not alter the response of retinal and optic nerve head blood flow to flicker stimulation.
PURPOSE It has been shown that stimulation with diffuse luminance flicker induces vasodilatation in the human retina and increases optic nerve head (ONH) blood flow. The present study was designed to investigate the influence of a short-term increase in intraocular pressure on flicker-induced changes in ONH blood flow and retinal vessel diameters. METHODS In a group of 15 healthy volunteers, ...
متن کاملEvaluation of Carpal Tunnel Syndrome by Laser Doppler Flowmetry
Background:Autonomic disturbance can leads to blood flow changes that can be studied by various methods. Objective: To assess the blood flow changes in patients with severe carpal tunnel syndrome by laser Doppler flowmetry Methods:Ten patients with severe unilateral carpal tunnel syndrome confirmed by electrodiagnostic examination enrolled in this study. Patients comprised one man and nine wom...
متن کاملAlterations in the vascular β-adrenoceptors of the rabbit knee joint due to acute inflammation
It has been shown that acute inflammation reduces the effectiveness of sympathetic nerves in the regulation of knee joint blood flow. To investigate the role of vascular β- adrenoceptors in this event, 12 NZW rabbits were maintained anaesthetized by 1 % halothane in N2O/O2, and acute knee joint inflammation was induced by intra-articular injection of 1 ml of 2% carageenan solution 24 hours be...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of biomedical optics
دوره 18 12 شماره
صفحات -
تاریخ انتشار 2013