Effect-site modelling of propofol using auditory evoked potentials.

نویسندگان

  • M White
  • M J Schenkels
  • F H Engbers
  • A Vletter
  • A G Burm
  • J G Bovill
  • G N Kenny
چکیده

Auditory evoked potentials (AEP) were used to monitor central nervous system effects during induction and recovery from anaesthesia produced by infusion of propofol 30 mg kg-1 h-1 in 22 healthy male patients. Non-parametric and parametric modelling techniques were used successfully to calculate the parameter keo which linked pharmacokinetic with pharmacodynamic aspects of drug action in only 15 of the study patients. In the non-parametric analysis, keo was found to have a mean value of 0.2 (range 0.1-0.36) min-1. Estimation of keo allowed calculation of the effect-site concentration (Ce50) associated with 50% of AEP effect for the population (2.08 micrograms ml-1; 95% confidence limits 1.7-2.45). There were no significant differences between keo values calculated by non-parametric and individual parametric modelling techniques. During recovery, 50% of patients demonstrated evidence of waking at an effect-site concentration of 2.28 micrograms ml-1.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Relationship between bispectral index, auditory evoked potential index and effect-site EC50 for propofol at two clinical end-points.

BACKGROUND Many anaesthetists are deterred from using total i.v. anaesthesia because of uncertainty over the concentration of propofol required to prevent awareness. We predicted blood and effect-site concentrations of propofol at two clinical end-points: loss of consciousness and no response to a painful stimulus. METHODS Forty unpremedicated Caucasian patients were anaesthetized with i.v. p...

متن کامل

New composite index based on midlatency auditory evoked potential and electroencephalographic parameters to optimize correlation with propofol effect site concentration: comparison with bispectral index and solitary used fast extracting auditory evoked potential index.

BACKGROUND This study investigates the accuracy of a composite index, the A-Line(R) auditory evoked potentials index version 1.6 (AAI1.6; Danmeter A/S, Odense, Denmark), as a measure of cerebral anesthetic drug effect in a model for predicting a calculated effect site concentration of propofol (CePROP). The AAI1.6 algorithm extracts information from the midlatency auditory evoked potentials, th...

متن کامل

A comparison between bispectral index analysis and auditory-evoked potentials for monitoring the time to peak effect to calculate the plasma effect site equilibration rate constant of propofol.

BACKGROUND AND OBJECTIVES To the best of our knowledge, the value of the plasma effect site equilibration rate constant (k(e0)) of propofol has not been reported in Chinese patients. The aim of this prospective, randomized study was to examine the characteristics of the time to peak effect (T(PEAK)) of propofol, a pharmacokinetic-independent descriptor of blood-brain equilibration, and k(e0) de...

متن کامل

Effect of propofol anaesthesia on the event-related potential mismatch negativity and the auditory-evoked potential N1.

BACKGROUND Studies on the effects of anaesthesia on event-related potentials and long latency auditory-evoked potentials (AEP) are sparse. Both provide information on cortical processing and may have potential as monitors of awareness. We studied the effect of propofol on the event-related potential mismatch negativity (MMN) and the long-latency AEP NI. METHODS Twenty-one patients received 1 ...

متن کامل

Effect of propofol on the auditory evoked response and oesophageal contractility.

Six patients were anaesthetized with 70% nitrous oxide in oxygen supplemented by infusion of propofol 40, 80, 120, 160 and 200 micrograms kg-1 min-1 sequentially in successive 10-min periods. Auditory evoked response (AER) and lower oesophageal contractility (LOC) were monitored. The AER findings were consistent with those noted in previous studies of i.v. agents. Early cortical waves showed at...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 82 3  شماره 

صفحات  -