Transient Reduction in Pulse-Based Impedance Measurements
نویسندگان
چکیده
Abstrac t Impedance measurements based on voltage pulse injection and current detection are faster and easier to implement than measurements based on sine waves, but transients produced in the current-to-voltage conversion may lead to large deviations in the measurement result. Because those transients depend on the same impedance being measured, solutions based on specific circuit values fail for large measurement ranges. We propose to reduce those transients by controlling the rise time of the pulse being applied to the impedance under test. For a particular implementation of the method, transient amplitude has been reduced to less than 1 % of the full scale voltage, as compared to 40 % overshoot when faster voltage pulses were applied.
منابع مشابه
Pulsed Transient Tissue Conductivity Measurement
We present an alternative technique forr obtaining tissue conductivity as a function of frequency. Pulsed transient tissue impedance measurement differs significantly from other commonly used swept frequency techniques in that the conductivity of a tissue sample can be obtained from a voltage transient response to a CW:Tent pulse. By obtaining the conductivity across a band of frequencies from ...
متن کاملFast Impedance Spectroscopy Method Using Square Pulse Excitation
The paper presents a fast impedance spectroscopy method for objects with very high impedance |Zx|≥1GΩ modeled by multi-element two-terminal RC networks. The method is based on analysis of the object response in the time domain after square pulse excitation. The object impedance spectrum was obtained using continuous Fourier transform. Simulation tests were performed for different excitation pul...
متن کاملEffect of cell electroporation on the conductivity of a cell suspension.
An increased permeability of a cell membrane during the application of high-voltage pulses results in increased transmembrane transport of molecules that otherwise cannot enter the cell. Increased permeability of a cell membrane is accompanied by increased membrane conductivity; thus, by measuring electric conductivity the extent of permeabilized tissue could be monitored in real time. In this ...
متن کاملCross Entropy-Based High-Impedance Fault Detection Algorithm for Distribution Networks
The low fault current of high-impedance faults (HIFs) is one of the main challenges for the protection of distribution networks. The inability of conventional overcurrent relays in detecting these faults results in electric arc continuity that it causes the fire hazard and electric shock and poses a serious threat to human life and network equipment. This paper presents an HIF detection algori...
متن کاملPulse pressure velocity measurement - a wearable sensor
Pulse pressure velocity measurements (PPV) may be a source of useful information on artery state. A 2007 guideline of the European Society of Hypertension recommends assessing arterial stiffness in patients with arterial hypertension, by measuring the PPV. Mechanical changes in the cardiovascular tree involved in the blood ejection have been measured at the thorax level and on the wrist using i...
متن کامل