Microtensile bond strength of different adhesive systems to primary and permanent dentin.

نویسندگان

  • Fabio Zovico Maxnuck Soares
  • Rachel de Oliveira Rocha
  • Daniela Prócida Raggio
  • Fernanda Tranchesi Sadek
  • Paulo Eduardo Capel Cardoso
چکیده

PURPOSE The aims of this in vitro study were to: (1) compare bond strength of different adhesive systems to primary and permanent dentin using microtensile test; and (2) evaluate the interaction of these materials to primary and permanent dentin by means of scanning electron microscopy (SEM). METHODS Middle-coronal dentin surfaces of 18 exfoliated primary and 18 extracted permanent molars were exposed and teeth were randomly divided, according to their adhesive system, into 3 groups (N=6 per group): (1) Clearfil SE Bond (SE); (2) One Up Bond F (OU); and (3) Single Bond (SB). Then, 5-mm high composite blocks were constructed. After bonding procedures, the teeth were stored in distilled water at 37 degrees C for 24 hours prior to the specimens' preparation. For the microtensile test, teeth (N=5 per group) were longitudinally sectioned into 2 axes rendering beam-specimens that were glued to special devices, which were mounted in a Universal Testing Machine to be loaded under a crosshead speed of 1 mm/min until fracture. One tooth of each group was prepared for SEM. RESULTS Microtensile bond strength mean values (MPa) to primary/permanent dentin were: (1) SE=60.0/61.4; (2) OU=54.5/53.3; and (3) SB=70.1/64.9. Two-way analysis of variance (ANOVA) showed no significant differences (P>.05) for the bond strength values among primary and permanent dentin groups, neither among groups SExSB and SExOU. SEM images of SE and SB showed a well-defined, uniform, and continuous hybrid layer. A continuous hybrid layer, however, was not found for OU. CONCLUSIONS Bond strength and micromorphologic characteristics of the adhesive systems evaluated were not influenced by the substrate. OU achieved worse results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Microtensile bond strength of clearfil SE bond to caries-affected dentin and normal dentin

Microtensile bond strength of clearfil SE bond to caries-affected dentin and normal dentin Dr. A. Ghasemi* - Dr. M. Bargrizan** - Dr. M. Mahmoodi*** *- Assistant Professor of Operative Dentistry Dept. - Faculty of Dentistry – Shaheed Beheshti University of Medical Sciences. **- Assistant Professor of Pedodontics Dept. - Faculty of Dentistry – Shaheed Beheshti University of Medical Sciences. ***...

متن کامل

Effect of Different Bonding Strategies on Adhesion to Deep and Superficial Permanent Dentin

OBJECTIVES To evaluate the effect of different bonding strategies on the microtensile bond strength to deep and superficial permanent dentin. METHODS Forty-eight teeth were randomly flattened according to the dentin depth: superficial dentin (SD) and deep dentin (DD). Subsequently, three adhesive systems were applied (n=8): an etch-and-rinse (Adper Single Bond 2 - SB), a "mild" two-step self-...

متن کامل

Sodium fluoride addition to a two-step etch-and-rinse adhesive system: effect on dentin microtensile bond strength and durability

Introduction: Studies have suggested that sodium fluoride (NaF) has an inhibitory effect on the activity of endogenous matrix metalloproteinase enzymes. This study assessed the effect of a fluoride-containing adhesive on microtensile bond strength (µTBS) over time. Material & Methods: In this experimental study, 36 extracted  third molars were used to evaluate the µTBS of...

متن کامل

Shear bond strength of different adhesive systems to normal and caries-affected dentin

BACKGROUND AND AIM: According to the effect of the adhesive and substrate type on the bond strength, examination of the adhesive is required in all aspects. The aim of this study was to evaluate the shear bond strength of different adhesive systems to normal dentin (ND) and caries affected dentin (CAD) in permanent teeth. METHODS: Thirty extracted molars with small occlusal caries were selected...

متن کامل

Microtensile bond strength of different adhesive systems in dentin irradiated with Er:YAG laser

The objective this study was to evaluate in vitro the bond strength of two etch-and-rise and one self-etching adhesive system after dentin irradiation with Er:YAG (erbium: yttrium aluminum garnet) laser using microtensile test. The results revealed that the groups treated with laser Er:YAG presented less tensile bond strength, independently to the adhesive system used. The prompt L-pop adhesive...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Pediatric dentistry

دوره 27 6  شماره 

صفحات  -

تاریخ انتشار 2005